Fan runs constantly
Items Procedures
Symptoms
Fan never stops running
Generates heat
Decreased computer
performance
Possible causes
BIOS not up to date.
Thermal condition (fan, air ow)--fan may not be defective but must run constantly to
remove excess heat generated by electrical components.
Inappropriate conguration.
Troubleshooting steps
General actions
1. Verify whether BIOS is set to Fan Always on while on AC Power F10 Setup. When
booting the computer, press F10 to open Setup, and then select Advanced > Built-In
Device Options Menu.
2. Update BIOS and drivers (4. Update BIOS and drivers on page 91) and reset BIOS to
default. BIOS may implement new fan characteristics and updates for other
components.
3. Perform a hard reset (8. Hard reset on page 100). Performing a hard reset can reset
recorded thermal values in memory.
Thermal-related issue
1. Verify fan is spinning. Reseat fan cable before moving to next step.
a. Check fan and connection. Reseat fan cable.
b. Be sure that no obstructions or dust are in heat sink fan, heat sink n, or vent.
c. Test fan using HP PC Hardware Diagnostics (UEFI) tool (6. HP Hardware
Diagnostics and Tools on page 92). Be sure that the fan is not producing loud
noise and that fan blades spin correctly.
d. Test with a veried working fan.
e. Replace the fan.
2. Verify thermal solution
Use Thermal Monitor tool (available only to authorized service providers/technicians)
(HP Thermal Monitor on page 95) to run stress test (processor and GPU) and verify that
thermal sensors are within limits after thermal condition is serviced.
User conguration
Change Power Options in Windows (i.e., choosing Balanced mode instead of High
performance). High performance and extensive graphics may cause the fan run constantly
to release the heat.
Notes BIOS currently omits fan presence detection to shorten boot time delay less than four
seconds. Therefore, the fan error is generated based on previous boot to operating system
that found system fan error.
Fan often is part of thermal solution, including heat sink, heat sink n/muer, and thermal
grease. Fan replacement requires reboot and fan function verication using HP PC Hardware
Diagnostics (UEFI) tool.