Error messages 117
Logical drive state: The current array controller is performing capacity expansion,...
...extension, or migration on this logical drive.
Action: No action is required. Further configuration is disabled until the process completes.
Logical drive state: The logical drive is disabled from a SCSI ID conflict.
Action: Check all SCSI components to make sure they all have a unique SCSI ID.
Logical drive state: The logical drive is not configured.
Action: Refresh the system using the Array Configuration Utility.
Logical drive state: The logical drive is not yet available.
Action: No action is required. This logical drive will remain in this state until all expand/shrink or move
operations on this array are completed. All I/O requests sent to the logical drive in this state will be rejected.
Logical drive state: The logical drive is offline from being ejected.
Action: Reinstall the removed physical drives.
Logical drive state: The logical drive is queued for erase.
Action: No action is required. Logical drive migrate and extend operations are not possible while the erase
operation is in progress.
Logical drive state: The logical drive is queued for expansion.
Action: No action is required.
Logical drive state: The logical drive is queued for rebuilding.
Action: No action is required. Normal operations can occur; however, performance will be less than optimal
during the rebuild process.
Logical drive state: This logical drive has a high physical drive count...
...as well as a high stripe size value such that a controller lock up could occur. It is recommended that the stripe size be
migrated to a lower value.
Action: Migrate the stripe size to a lower value using the Array Configuration Utility.
NVRAM Error: Board ID could not be read...
...(Read-Only Table failed checksum test). Unrecoverable error.
Action: Contact HP support ("Contacting HP" on page 185, "Contacting HP technical support or an
authorized reseller" on page 185).
NVRAM Error: Bootstrap NVRAM image failed checksum test,...
...but a backup image was found and successfully restored. A system restart is needed.
Action: Restart the server.