Error messages 99
Identify Logical Drive Data did not Match with NVRAM
Description: The identify unit data from the array controller does not match with the information stored in
NVRAM. This can occur if new, previously configured drives have been placed in a system that has also been
previously configured.
Action: Run the server setup utility to configure the controller and NVRAM.
Insufficient adapter resources
Description: The adapter does not have sufficient resources to perform posted-write operations to the array
accelerator board. Drive rebuild may be occurring.
Action: Operate the system without the array accelerator board until the drive rebuild completes.
Inter-Controller Link Connection Could Not Be Established
Description: Unable to communicate over the link connecting the redundant controllers.
Action: Be sure both controllers are using the same hardware and firmware revisions. If one controller failed,
replace it.
Less Than 75% Batteries at Sufficient Voltage
Description: The operation of the array accelerator board has been disabled due to less than 75% of the
battery packs being at the sufficient voltage level.
Action: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours.
Less Than 75% of Batteries at Sufficient Voltage Battery Pack X Below Reference
Voltage
Description: Battery pack on the array accelerator is below the required voltage levels.
Action: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours.
Logical Drive X Failed Due to Cache Error
Description: This logical drive failed due to a catastrophic cache error.
Action: Replace the array accelerator board and reconfigure using ACU.
Logical Drive X Status = Failed
Description: This status could be issued for several reasons:
Logical drive is configured for No Fault Tolerance, and one or more drives failed.
Mirroring is enabled, and any two mirrored drives failed.
Data Guarding is enabled, and two or more drives failed.
Another configured logical drive is in the WRONG DRIVE REPLACED or LOOSE CABLE DETECTED
state.
Action: Check for drive failures, wrong drive replaced, or loose cable messages. If a drive failure occurred,
replace the failed drive or drives, and then restore the data for this logical drive from the tape backup.