HP DL120 - ProLiant - G5 Troubleshooting Guide Page 179

  • Download
  • Add to my manuals
  • Print
  • Page
    / 201
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 178
Error messages 179
Location LED codes
Power Supply - Slot 3
3-1 or 3-2
Power Supply - Slot 4
4-1 or 4-2
Power Supply - Slot 5
5-1 or 5-2
Power Supply - Slot 6
6-1 or 6-2
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Reseat the power supply.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website
(http://www.hp.com/products/servers/proliant-bl/p-class/info).
2. Reseat the power management module.
3. Replace the power supply.
Power management module board error codes
LED code: 7-1, 7-2, 7-3, 7-4, 7-5, 7-6, 7-7, 7-8, 7-9, 7-10, 7-11, 7-12, or 7-13
Location: Power management board
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Reseat the power management module.
2. Replace the power management module.
Power management module backplane error codes
LED code: 8-1, 8-2, 8-3, 8-4, 8-5, 8-6, 8-7, or 8-8
Location: Power management backplane
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the power management module reset button.
Unknown power management module error code
LED code: 19-1
Location: Unknown
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the power management module reset button.
Port 85 codes and iLO messages
Troubleshooting the system using port 85 codes
1. Locate the port 85 code display.
IMPORTANT: Be sure the port 84/85 switch is set to display port 85 codes.
2. Locate the code in the following table.
Page view 178