HP DL120 - ProLiant - G5 Troubleshooting Guide Page 98

  • Download
  • Add to my manuals
  • Print
  • Page
    / 201
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 97
Error messages 98
Drive Monitoring Features Are Unobtainable
Description: ADU ("Array diagnostic software" on page 76) is unable to get monitor and performance data
due to a fatal command problem (such as drive time-out), or is unable to get data due to these features not
being supported on the controller.
Action: Check for other errors such as time-outs. If no other errors occur, upgrade the firmware to a version
that supports monitor and performance, if desired.
Drive Monitoring is NOT Enabled for SCSI Port X Drive ID Y
Description: The monitor and performance features have not been enabled on this drive.
Action: Run the server setup utility to initialize the monitor and performance features.
Drive Time-Out Occurred on Physical Drive Bay X
Description: ADU issued a command to a physical drive and the command was never acknowledged.
Action: The drive or cable may be bad. Check the other error messages on the Diagnostics screen to
determine resolution.
Drive X Indicates Position Y
Description: Message indicates a designated physical drive, which seems to be scrambled or in a drive bay
other than the one for which it was originally configured.
Action:
1. Examine the graphical drive representation on ADU ("Array diagnostic software" on page 76) to
determine proper drive locations.
2. Power down the server.
3. Remove drive X and place it in drive position Y.
4. Rearrange the drives according to the ADU instructions.
Duplicate Write Memory Error
Description: Data cannot be written to the array accelerator board in duplicate due to the detection of parity
errors. This is not a data-loss situation.
Action: Replace the array accelerator board.
Error Occurred Reading RIS Copy from SCSI Port X Drive ID
Description: An error occurred while ADU ("Array diagnostic software" on page 76) was trying to read the
RIS from this drive.
Action: HP stores the hard drive configuration information in the RIS. If multiple errors occur, the drive may
need to be replaced.
FYI: Drive (Bay) X is Third-Party Supplied
Description: Third-party supplied the installed drive.
Action: If problems exist with this drive, replace it with a supported drive.
Page view 97
1 2 ... 93 94 95 96 97 98 99 100 101 102 103 ... 200 201

Comments to this Manuals

No comments