HP rp2450 Manual Page 139

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 138
Chapter
Secure Web Console I/O Card Replacement
147
CAUTION For system security, initial configuration must be completed before making the serial
connection between the SWC card and the server’s console port.
Failure to follow this precaution can result in root level access being available to any
level of SWC user.
Step 3. Connect the server’s console to the SWC card via the RS 232 Serial port.
Step 4. Perform Initial Configuration of the SWC card.
a. Ensure that no other devices (printers, etc.) are connected on the same local subnet by
disconnecting the LAN cable from the SWC and using the Ping command as follows:
C:\ ping 192.0.0.192
It will time out.
b. At a command line prompt, enter the following:
C:\route add 192.0.0.192 xx.xx.xx.xx.xx
Where xx.xx.xx.xx.xx is the IP address of your PC or Unix workstation.
c. Reconnect the LAN cable to the SWC card and use a PC or Unix Workstation and a web
browser. Verify that you can access the SWC at its default IP address using the Ping command
as follows:
C:\ping 192.0.0.192
It will indicate connection with the SWC card at IP 192.0.0.192
Step 5. Create the first SWC administrator account.
RS 232 Serial Port