Hp ProLiant DL585 Server User Manual

Browse online or download User Manual for Computer hardware Hp ProLiant DL585 Server. HP ProLiant DL585 Server User Manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 183
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - User Guide

HP ProLiant DL585 Server User Guide April 2005 (Fifth Edition) Part Number 358707-005

Page 2

About This Guide x HP ProLiant DL585 Server User Guide This symbol indicates the presence of hazardous energy circuits or electric shock ha

Page 3 - Contents

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-3 Saving RBSU configuration settings RBSU automatically saves settin

Page 4

Server Configuration and Utilities 5-4 HP ProLiant DL585 Server User Guide System options The System Options menu is for overall system confi

Page 5

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-5 PCI-X devices The PCI-X Devices menu option enables you to view an

Page 6

Server Configuration and Utilities 5-6 HP ProLiant DL585 Server User Guide Automatic Server Recovery The Automatic Server Recovery menu inclu

Page 7

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-7 Utility language The Utility Language menu enables you to set the

Page 8

Server Configuration and Utilities 5-8 HP ProLiant DL585 Server User Guide Table 5-1: RBSU default settings Menu/option Default setting Sys

Page 9

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-9 Table 5-1: RBSU default settings continued Menu/option Default se

Page 10 - About This Guide

Server Configuration and Utilities 5-10 HP ProLiant DL585 Server User Guide Enhanced auto-configuration process During the power-up sequence

Page 11 - Symbols in text

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-11 Integrated Lights-Out technology Integrated Lights-Out (iLO) is a

Page 12 - Technical support

Server Configuration and Utilities 5-12 HP ProLiant DL585 Server User Guide 5. Exit iLO RBSU. HP recommends using DNS/DHCP with iLO to simpl

Page 13 - HP website

About This Guide HP ProLiant DL585 Server User Guide xi Rack stability WARNING: To reduce the risk of personal injury or damage to the equ

Page 14 - Server features

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-13 Safety and security benefits When you flash the system ROM, ROMPa

Page 15

Server Configuration and Utilities 5-14 HP ProLiant DL585 Server User Guide System Online ROM flash component utility The Online ROM Flash Co

Page 16 - Server operations

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-15 ROM legacy USB support When using operating systems that support

Page 17 - Power on/Standby buttons (2)

Server Configuration and Utilities 5-16 HP ProLiant DL585 Server User Guide ProLiant Essentials Foundation Pack The ProLiant Essentials Found

Page 18

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-17 • Legacy Intelligent Manageability products—Many legacy products

Page 19

Server Configuration and Utilities 5-18 HP ProLiant DL585 Server User Guide HP Systems Insight Manager HP SIM is a Web-based application that

Page 20

Server Configuration and Utilities HP ProLiant DL585 Server User Guide 5-19 Integrated Management Log The IML records hundreds of events and

Page 21

HP ProLiant DL585 Server User Guide A-1 A Regulatory compliance notices Regulatory compliance model number For the purpose of regulatory comp

Page 22 - Removing the access panel

Regulatory compliance notices A-2 HP ProLiant DL585 Server User Guide The FCC rating label on the device shows the classification (A or B) of

Page 23 - Installing the access panel

Regulatory compliance notices HP ProLiant DL585 Server User Guide A-3 Declaration of conformity for products marked with the FCC logo, United

Page 24 - Server setup

About This Guide xii HP ProLiant DL585 Server User Guide Related documents For additional information on the topics covered in this guide, re

Page 25 - Rack planning resources

Regulatory compliance notices A-4 HP ProLiant DL585 Server User Guide Cables Connections to this device must be made with shielded cables wit

Page 26 - Optimum environment

Regulatory compliance notices HP ProLiant DL585 Server User Guide A-5 European Union regulatory notice This product complies with the follow

Page 27 - Temperature requirements

Regulatory compliance notices A-6 HP ProLiant DL585 Server User Guide Japanese notice BSMI notice

Page 28 - Power requirements

Regulatory compliance notices HP ProLiant DL585 Server User Guide A-7 Korean notices Class A equipment Class B equipment

Page 29 - Grounding requirements

Regulatory compliance notices A-8 HP ProLiant DL585 Server User Guide Laser compliance This product may be provided with an optical storage d

Page 30 - Rack warnings and cautions

Regulatory compliance notices HP ProLiant DL585 Server User Guide A-9 Battery replacement notice Your computer is equipped with an internal l

Page 31 - Server shipping contents

Regulatory compliance notices A-10 HP ProLiant DL585 Server User Guide Taiwan battery recycling notice The Taiwan EPA requires dry battery ma

Page 32 - • Options to be installed

Regulatory compliance notices HP ProLiant DL585 Server User Guide A-11 Power cord statement for Japan

Page 33 - 1. Mark the rack

HP ProLiant DL585 Server User Guide B-1 B Electrostatic discharge To prevent damaging the system, be aware of the precautions you need to fol

Page 34

Electrostatic discharge B-2 HP ProLiant DL585 Server User Guide Grounding methods There are several methods for grounding. Use one or more of

Page 35

About This Guide HP ProLiant DL585 Server User Guide xiii HP contact information For the name of the nearest HP authorized reseller: • In th

Page 36

HP ProLiant DL585 Server User Guide C-1 C System battery The servers have memory devices that require a battery to retain stored information.

Page 37

System battery C-2 HP ProLiant DL585 Server User Guide Figure C-1: Battery location on the system board 5. Remove the existing battery. F

Page 38

System battery HP ProLiant DL585 Server User Guide C-3 6. Install the new battery. Figure C-3: Installing a new battery 7. Install the ac

Page 39

HP ProLiant DL585 Server User Guide D-1 D Cabling guidelines Cabling a SCSI controller CAUTION: Route the SCSI cables through the SCSI cab

Page 40

Cabling guidelines D-2 HP ProLiant DL585 Server User Guide Cabling an optional SCSI controller to the 4 x 1 drive cage in simplex mode Figur

Page 41 - Connecting the power cord

Cabling guidelines HP ProLiant DL585 Server User Guide D-3 Cabling the optional SAS hard drive cage Connecting and routing the cables Figure

Page 42

Cabling guidelines D-4 HP ProLiant DL585 Server User Guide Cabling the optional SAS or SATA controller Figure D-4: Cabling the SAS hard dri

Page 43

HP ProLiant DL585 Server User Guide E-1 E System LEDs and switches This appendix provides information about locating and using system LEDs an

Page 44

System LEDs and switches E-2 HP ProLiant DL585 Server User Guide Front panel LEDs Figure E-1: Front panel LEDs Table E-1: Front panel LED

Page 45

System LEDs and switches HP ProLiant DL585 Server User Guide E-3 Hot-plug SCSI hard drive LEDs Figure E-2: Hot-plug SCSI hard drive LEDs T

Page 46

HP ProLiant DL585 Server User Guide 1-1 1 Server features The HP ProLiant DL585 Server is the ideal solution for enterprise customers who req

Page 47

System LEDs and switches E-4 HP ProLiant DL585 Server User Guide Table E-3: Hot-plug SCSI hard drive LED combinations Activity LED Online L

Page 48

System LEDs and switches HP ProLiant DL585 Server User Guide E-5 Hot-plug SAS or SATA hard drive LEDs Figure E-3: Hot-plug SAS or SATA hard

Page 49

System LEDs and switches E-6 HP ProLiant DL585 Server User Guide Table E-5: Hot-plug SAS or SATA hard drive LED combinations Online/Activi

Page 50

System LEDs and switches HP ProLiant DL585 Server User Guide E-7 Table E-5: Hot-plug SAS or SATA hard drive LED combinations continued Onlin

Page 51 - Routine maintenance

System LEDs and switches E-8 HP ProLiant DL585 Server User Guide Hot-plug power supply LEDs Figure E-5: Hot-plug power supply LEDs Table E

Page 52 - Installing hardware options

System LEDs and switches HP ProLiant DL585 Server User Guide E-9 NIC LEDs Figure E-6: NIC LEDs Table E-8: NIC LEDs Item Description LED c

Page 53 - Processor memory boards

System LEDs and switches E-10 HP ProLiant DL585 Server User Guide BBWCE LEDs Figure E-7: BBWCE LEDs Table E-9: BBWCE LED descriptions Ser

Page 54

System LEDs and switches HP ProLiant DL585 Server User Guide E-11 Table E-9: BBWCE LED descriptions continued Server status LED color LED

Page 55

System LEDs and switches E-12 HP ProLiant DL585 Server User Guide QuickFind diagnostic display LEDs Figure E-8: QuickFind diagnostic displa

Page 56

System LEDs and switches HP ProLiant DL585 Server User Guide E-13 Table E-10: QuickFind diagnostic display LEDs continued Item Description

Page 57

Server features 1-2 HP ProLiant DL585 Server User Guide The HP ProLiant DL585 Server achieves unparalleled ease of manageability and servicea

Page 58

System LEDs and switches E-14 HP ProLiant DL585 Server User Guide Table E-10: QuickFind diagnostic display LEDs continued Item Description

Page 59

System LEDs and switches HP ProLiant DL585 Server User Guide E-15 System board switches Some server operations, including adding or removing

Page 60 - Memory options

System LEDs and switches E-16 HP ProLiant DL585 Server User Guide System maintenance switch (SW3) Figure E-9: System maintenance switch (SW

Page 61 - Minimum memory requirements

System LEDs and switches HP ProLiant DL585 Server User Guide E-17 Table E-11: System maintenance switch (SW3) continued Position Default Fu

Page 62 - Figure 4-10: DIMM slots

System LEDs and switches E-18 HP ProLiant DL585 Server User Guide System ID switch (SW4) Figure E-10: System ID switch (SW4) Table E-12:

Page 63 - Figure 4-11: DIMM slots

System LEDs and switches HP ProLiant DL585 Server User Guide E-19 iLO/Redundant ROM override switch (SW5) The iLO/Redundant ROM override swit

Page 64

HP ProLiant DL585 Server User Guide F-1 F Server error messages Use POST error messages to assist in troubleshooting and performing basic dia

Page 65

HP ProLiant DL585 Server User Guide G-1 G Server specifications Server specifications This appendix provides operating and performance specif

Page 66

Server specifications G-2 HP ProLiant DL585 Server User Guide Table G-1: Server specifications continued Feature Units Power supply output p

Page 67

HP ProLiant DL585 Server User Guide H-1 H Troubleshooting This appendix provides specific troubleshooting information for the server. Use it

Page 68 - 3. Remove the hard drive

HP ProLiant DL585 Server User Guide 2-1 2 Server operations Powering up the server To power up the server, press the Power on/Standby butto

Page 69

Troubleshooting H-2 HP ProLiant DL585 Server User Guide This appendix includes the following topics: • If the server does not start You are

Page 70

Troubleshooting HP ProLiant DL585 Server User Guide H-3 If the server does not start This section provides systematic instructions on what to

Page 71

Troubleshooting H-4 HP ProLiant DL585 Server User Guide IMPORTANT: If the server does not restart, proceed to the following section, “Diagn

Page 72

Troubleshooting HP ProLiant DL585 Server User Guide H-5 Diagnostic steps If the server does not power up or powers up but does not complete P

Page 73

Troubleshooting H-6 HP ProLiant DL585 Server User Guide Table H-2: Is the system power LED off? Answer Possible reasons Possible solutions T

Page 74

Troubleshooting HP ProLiant DL585 Server User Guide H-7 Table H-3: Is the system power LED green? Answer Possible reasons Possible solution

Page 75

Troubleshooting H-8 HP ProLiant DL585 Server User Guide Table H-4: Is the external health LED green? Answer Possible reasons Possible solut

Page 76

Troubleshooting HP ProLiant DL585 Server User Guide H-9 Table H-5: Is the internal health LED green? Answer Possible reasons Possible solut

Page 77 - 1. Prepare the hard drive

Troubleshooting H-10 HP ProLiant DL585 Server User Guide Table H-5: Is the internal health LED green? continued Answer Possible reasons Poss

Page 78

Troubleshooting HP ProLiant DL585 Server User Guide H-11 PPM or board power fault Inspect the QuickFind diagnostic display panel to determ

Page 79 - Universal media bays

Server operations 2-2 HP ProLiant DL585 Server User Guide 3. If the server is installed in a rack, press the UID LED button (1) on the front

Page 80

Troubleshooting H-12 HP ProLiant DL585 Server User Guide Table H-6: Is the monitor displaying information? Answer Possible reasons Possible

Page 81

Troubleshooting HP ProLiant DL585 Server User Guide H-13 Problems after initial boot After the server has passed POST, you might still encoun

Page 82 - Table 4-7: Hot-plug fans

Troubleshooting H-14 HP ProLiant DL585 Server User Guide Table H-7: Problems after initial boot continued Problem Possible reasons Possible

Page 83 - Replacing a hot-plug fan

Troubleshooting HP ProLiant DL585 Server User Guide H-15 CAUTION: The System Erase Utility causes loss of all configuration information, a

Page 84

Troubleshooting H-16 HP ProLiant DL585 Server User Guide Other information resources Refer to the following additional information for help.

Page 85 - Table 4-8: Power supplies

HP ProLiant DL585 Server User Guide Index-1 Index A access panels opening 2-7 removing 2-7 adding See installing air flow requirements

Page 86

Index Index-2 HP ProLiant DL585 Server User Guide 5i Plus Memory Module D-4 Battery-Backed Write Cache Enabler 4-46 hard drives D-1 har

Page 87

Index HP ProLiant DL585 Server User Guide Index-3 F fan cage, removing 4-44 fans, hot-plug front fan cage, removing 4-44 LED E-7 LED, l

Page 88

Index Index-4 HP ProLiant DL585 Server User Guide hot-plug power supplies See power supplies, hot-plug hot-plug SAS hard drive See hard d

Page 89 - PCI-X expansion boards

Index HP ProLiant DL585 Server User Guide Index-5 iLO/Redundant ROM Override switch (SW5) E-19 media drives 4-28 memory 4-3 power suppl

Page 90 - Performance balancing

Server operations HP ProLiant DL585 Server User Guide 2-3 Locating and removing the Torx T-15 tool 1. Locate the Torx T-15 tool on the back

Page 91

Index Index-6 HP ProLiant DL585 Server User Guide personal injury, warning 4-1 POST error messages F-1, H-12 power cord connecting 3-18

Page 92

Index HP ProLiant DL585 Server User Guide Index-7 measuring 3-10 rail release levers locating 2-6 warning 2-6 RBSU See ROM-Based Setu

Page 93

Index Index-8 HP ProLiant DL585 Server User Guide options 4-20 SAS hard drive cage, cabling D-3 SAS hard drive ID numbers 4-25 SATA con

Page 94

Index HP ProLiant DL585 Server User Guide Index-9 locating E-18 settings E-18 system LEDs external E-1 internal E-1 system maintenanc

Page 95 - Installing the BBWCE

Server operations 2-4 HP ProLiant DL585 Server User Guide Extending the server from the rack 1. Loosen the thumbscrews that secure the serve

Page 96

© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Page 97

Server operations HP ProLiant DL585 Server User Guide 2-5 2. Extend the server on the rack rails until the server rail-release latches engag

Page 98

Server operations 2-6 HP ProLiant DL585 Server User Guide WARNING: Be careful when pressing the rail-release levers and sliding the compon

Page 99 - Navigating RBSU

Server operations HP ProLiant DL585 Server User Guide 2-7 Removing the access panel WARNING: Pressing the Power on/Standby button sets the

Page 100 - Using RBSU

Server operations 2-8 HP ProLiant DL585 Server User Guide Installing the access panel 1. Place the access panel on top of the server with th

Page 101

HP ProLiant DL585 Server User Guide 3-1 3 Server setup Optional installation services You can choose to have HP install the system. The insta

Page 102

Server setup 3-2 HP ProLiant DL585 Server User Guide Rack planning resources The rack resource kit ships with all HP 9000, 10000, and H9 seri

Page 103

Server setup HP ProLiant DL585 Server User Guide 3-3 Optimum environment When installing the server in a rack, select a location that meets t

Page 104

Server setup 3-4 HP ProLiant DL585 Server User Guide The HP 9000 and 10000 series racks provide proper server cooling from flow-through perfo

Page 105

Server setup HP ProLiant DL585 Server User Guide 3-5 Power requirements The installation of this equipment must be in accordance with local/r

Page 106

Server setup 3-6 HP ProLiant DL585 Server User Guide Grounding requirements For proper operation and safety, the server must be properly grou

Page 107

HP ProLiant DL585 Server User Guide iii Contents About This Guide Audience assumptions...

Page 108

Server setup HP ProLiant DL585 Server User Guide 3-7 Rack warnings and cautions WARNING: To reduce the risk of personal injury or equipmen

Page 109 - Redundant ROM support

Server setup 3-8 HP ProLiant DL585 Server User Guide Removing shipping bracket from PCI slots To remove the shipping bracket from the PCI slo

Page 110 - Safety and security benefits

Server setup HP ProLiant DL585 Server User Guide 3-9 In addition to these supplied items, you might need: • Application software diskettes •

Page 111

Server setup 3-10 HP ProLiant DL585 Server User Guide Installing the server into the rack Follow the steps in this section if you are install

Page 112 - ROM legacy USB support

Server setup HP ProLiant DL585 Server User Guide 3-11 2. From the front of the rack, identify the rear rack holes on the inside of the verti

Page 113 - Ships as standard

Server setup 3-12 HP ProLiant DL585 Server User Guide 5. Adjust the rack rail depth by sliding it forward. 6. Insert the two rail tabs from

Page 114 - Subscription service

Server setup HP ProLiant DL585 Server User Guide 3-13 9. Attach the server rails to the server. Figure 3-7: Attaching a server rail to the

Page 115 - Automatic Server Recovery

Server setup 3-14 HP ProLiant DL585 Server User Guide 11. Pull the inner slide rail forward from each rack rail assembly until it locks into

Page 116 - Integrated Management Log

Server setup HP ProLiant DL585 Server User Guide 3-15 CAUTION: Keep the server parallel to the floor when sliding the server rails into th

Page 117

Server setup 3-16 HP ProLiant DL585 Server User Guide 15. Reach around the front of the server to press the rail-release levers at the front

Page 118 - Class B equipment

Contents iv HP ProLiant DL585 Server User Guide Rack planning resources ...

Page 119 - Modifications

Server setup HP ProLiant DL585 Server User Guide 3-17 Connecting the power cord and peripheral devices WARNING: To reduce the risk of elec

Page 120 - Class B bquipment

Server setup 3-18 HP ProLiant DL585 Server User Guide Connecting the power cord WARNING: To reduce the risk of electric shock or damage to

Page 121

Server setup HP ProLiant DL585 Server User Guide 3-19 2. Secure the power cord with the retaining clip. Figure 3-14: Securing the power co

Page 122 - BSMI notice

Server setup 3-20 HP ProLiant DL585 Server User Guide Attaching the cable management arm The cable management arm ships with a round-hole bra

Page 123

Server setup HP ProLiant DL585 Server User Guide 3-21 Attaching the cable management arm to a round-hole rack 1. Remove the square-hole brac

Page 124 - Laser compliance

Server setup 3-22 HP ProLiant DL585 Server User Guide 2. Attach the round-hole bracket by pulling out the spring-activated fasteners on the

Page 125 - Battery replacement notice

Server setup HP ProLiant DL585 Server User Guide 3-23 4. Attach the cable management arm to the round-hole rack, and then secure the thumbsc

Page 126

Server setup 3-24 HP ProLiant DL585 Server User Guide Attaching the cable management arm to the server 1. Loosen the thumbscrews on the fron

Page 127

Server setup HP ProLiant DL585 Server User Guide 3-25 Securing the cables to the cable management arm 1. Align the pivot points of the cable

Page 128 - Electrostatic discharge

Server setup 3-26 HP ProLiant DL585 Server User Guide 3. Secure the cables to the inside of the cable management arm using the Velcro straps

Page 129 - Grounding methods

Contents HP ProLiant DL585 Server User Guide v Hot-plug SAS or SATA hard drive options...

Page 130 - System battery

Server setup HP ProLiant DL585 Server User Guide 3-27 Powering up and configuring the server To power up the server, press the Power on/Stand

Page 131

Server setup 3-28 HP ProLiant DL585 Server User Guide • Manual installation—Insert the operating system CD into the CD-ROM drive, and reboot

Page 132 - 6. Install the new battery

HP ProLiant DL585 Server User Guide 4-1 4 Installing hardware options If more than one option is being installed, read the installation instr

Page 133 - Cabling guidelines

Installing hardware options 4-2 HP ProLiant DL585 Server User Guide Processor memory boards The server supports up to four processor memory b

Page 134

Installing hardware options HP ProLiant DL585 Server User Guide 4-3 Figure 4-1: Locating the processor memory boards Table 4-1: Processor

Page 135

Installing hardware options 4-4 HP ProLiant DL585 Server User Guide Installing a processor memory board 1. Power down the server. Refer to “

Page 136 - Memory Module

Installing hardware options HP ProLiant DL585 Server User Guide 4-5 Upgrading processor memory boards To upgrade to a single core 2.6 GHz pro

Page 137 - System LEDs and switches

Installing hardware options 4-6 HP ProLiant DL585 Server User Guide 6. Reposition the BBWC cable by angling it toward the rear of the chassi

Page 138 - Table E-1: Front panel LEDs

Installing hardware options HP ProLiant DL585 Server User Guide 4-7 8. Attach the front foam piece to the Velcro on the side wall of the cha

Page 139

Installing hardware options 4-8 HP ProLiant DL585 Server User Guide 10. Separate the Velcro from the rear foam piece, and adhere it to the si

Page 140

Contents vi HP ProLiant DL585 Server User Guide Automatic Server Recovery...

Page 141

Installing hardware options HP ProLiant DL585 Server User Guide 4-9 14. Install the new processor memory boards. 15. Install the air baffles

Page 142

Installing hardware options 4-10 HP ProLiant DL585 Server User Guide Minimum memory requirements • Two DIMMs must be installed on the proces

Page 143 - Table E-6: Hot-plug fan LED

Installing hardware options HP ProLiant DL585 Server User Guide 4-11 Figure 4-10: DIMM slots Table 4-2: Processor memory board memory ba

Page 144 - Hot-plug power supply LEDs

Installing hardware options 4-12 HP ProLiant DL585 Server User Guide Memory population guidelines for processor memory boards with four DIMM

Page 145 - Table E-8: NIC LEDs

Installing hardware options HP ProLiant DL585 Server User Guide 4-13 Internal storage and media drives The server ships standard with a diske

Page 146 - Figure E-7: BBWCE LEDs

Installing hardware options 4-14 HP ProLiant DL585 Server User Guide Hot-plug SCSI hard drive options The server supports up to four hot-plug

Page 147

Installing hardware options HP ProLiant DL585 Server User Guide 4-15 Determining the proper hot-plug SCSI hard drive installation order The s

Page 148

Installing hardware options 4-16 HP ProLiant DL585 Server User Guide Guidelines for installing SCSI devices The following guidelines apply fo

Page 149

Installing hardware options HP ProLiant DL585 Server User Guide 4-17 Removing a hot-plug SCSI hard drive 1. Press the ejector lever release

Page 150

Installing hardware options 4-18 HP ProLiant DL585 Server User Guide Installing a hot-plug SCSI hard drive 1. Press the ejector lever releas

Page 151 - System board switches

Contents HP ProLiant DL585 Server User Guide vii Appendix D Cabling guidelines Cabling a SCSI controller...

Page 152

Installing hardware options HP ProLiant DL585 Server User Guide 4-19 Switching from duplex to simplex mode The server ships in duplex mode. T

Page 153

Installing hardware options 4-20 HP ProLiant DL585 Server User Guide Hot-plug SAS or SATA hard drive options The server supports installation

Page 154 - System ID switch (SW4)

Installing hardware options HP ProLiant DL585 Server User Guide 4-21 7. Loosen the thumbscrew, and remove the SCSI backplane. Figure 4-18:

Page 155

Installing hardware options 4-22 HP ProLiant DL585 Server User Guide 10. Route the SAS cables through the opening in the power transfer board

Page 156 - Server error messages

Installing hardware options HP ProLiant DL585 Server User Guide 4-23 11. Connect the cables to the connectors on the back of the SAS hard dri

Page 157 - Server specifications

Installing hardware options 4-24 HP ProLiant DL585 Server User Guide 14. Secure the SAS hard drive cage with the screws provided in the optio

Page 158

Installing hardware options HP ProLiant DL585 Server User Guide 4-25 Hot-plug SAS or SATA hard drive guidelines Figure 4-24: Hot-plug SAS o

Page 159 - Troubleshooting

Installing hardware options 4-26 HP ProLiant DL585 Server User Guide Installing a hot-plug SAS or SATA hard drive 1. Prepare the hard drive.

Page 160

Installing hardware options HP ProLiant DL585 Server User Guide 4-27 3. Close the ejector lever. Figure 4-26: Installing a hot-plug SAS or

Page 161 - If the server does not start

Installing hardware options 4-28 HP ProLiant DL585 Server User Guide Universal media bays The server supports installation of removable unive

Page 162

Contents viii HP ProLiant DL585 Server User Guide Problems after initial boot...

Page 163 - Table H-1: Diagnostic steps

Installing hardware options HP ProLiant DL585 Server User Guide 4-29 Removing a universal media drive 1. Power down the server. Refer to “Po

Page 164

Installing hardware options 4-30 HP ProLiant DL585 Server User Guide Installing a universal media drive 1. Power down the server. Refer to “

Page 165

Installing hardware options HP ProLiant DL585 Server User Guide 4-31 Hot-plug fans The server supports redundant hot-plug fans in an N+1 conf

Page 166

Installing hardware options 4-32 HP ProLiant DL585 Server User Guide Replacing a hot-plug fan 1. Extend the server from the rack. Refer to “

Page 167

Installing hardware options HP ProLiant DL585 Server User Guide 4-33 5. Install the replacement fan. Figure 4-33: Installing a hot-plug fa

Page 168

Installing hardware options 4-34 HP ProLiant DL585 Server User Guide Hot-plug power supplies IMPORTANT: Do not install the power supplies u

Page 169

Installing hardware options HP ProLiant DL585 Server User Guide 4-35 Removing a redundant hot-plug power supply or blank 1. If present, remo

Page 170

Installing hardware options 4-36 HP ProLiant DL585 Server User Guide Installing a redundant hot-plug power supply 1. Remove the protective c

Page 171 - Problems after initial boot

Installing hardware options HP ProLiant DL585 Server User Guide 4-37 6. Connect the power cord to AC inlet 2. Figure 4-37: Connecting the

Page 172

Installing hardware options 4-38 HP ProLiant DL585 Server User Guide PCI-X expansion boards The server supports the installation of both PCI

Page 173

HP ProLiant DL585 Server User Guide ix About This Guide This guide provides step-by-step instructions for installation and reference informa

Page 174 - Other information resources

Installing hardware options HP ProLiant DL585 Server User Guide 4-39 Table 4-9: PCI-X expansion slots and buses continued Item Slot Bus De

Page 175

Installing hardware options 4-40 HP ProLiant DL585 Server User Guide Installing an expansion board CAUTION: To avoid risk of damage to the

Page 176

Installing hardware options HP ProLiant DL585 Server User Guide 4-41 7. If you are installing a full-length board, press the PCI-X retaining

Page 177

Installing hardware options 4-42 HP ProLiant DL585 Server User Guide 10. Close the PCI-X retaining clip (for full-length expansion boards onl

Page 178

Installing hardware options HP ProLiant DL585 Server User Guide 4-43 BBWCE Features of the BBWCE include: • Protects against hard boot, powe

Page 179

Installing hardware options 4-44 HP ProLiant DL585 Server User Guide Installing the BBWCE 1. Power down the server. Refer to “Powering down

Page 180

Installing hardware options HP ProLiant DL585 Server User Guide 4-45 7. Align the BBWCE with the four stand-offs along the inside wall of th

Page 181

Installing hardware options 4-46 HP ProLiant DL585 Server User Guide 8. Connect the cable to the BBWCE and the 5i Plus Memory Module. Figur

Page 182

HP ProLiant DL585 Server User Guide 5-1 5 Server Configuration and Utilities This chapter provides information about the following utilities

Page 183

Server Configuration and Utilities 5-2 HP ProLiant DL585 Server User Guide ROM-Based Setup Utility RBSU is a configuration utility that is em

Comments to this Manuals

No comments