Table H-3: Is the system power LED green?
Answer Possible reasons Possible solutions
No The Power on/Standby button has not
been pressed firmly.
Firmly press the power button.
A power supply problem exists. The
power supply might not be connected
or inserted properly, it might have a
damaged connector, or it might have
failed.
Be sure that the power supply is
undamaged, the power supply is fully
seated, and the power supply LED is
green.
The system might have experienced a
short.
Look for bent connector pins and
improperly seated expansion boards.
The front panel LED assembly has
failed.
Be sure that the front panel LED
assembly cable is connected to the
power backplane.
If these solutions do not solve the
problem, contact an authorized
service provider for assistance.
Yes If the system power button LED is
green, refer to Table H-4.