Hp ProLiant DL585 Server User Manual Page 143

  • Download
  • Add to my manuals
  • Print
  • Page
    / 183
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 142
System LEDs and switches
HP ProLiant DL585 Server User Guide E-7
Table E-5: Hot-plug SAS or SATA hard drive LED combinations continued
Online/Activity LED
(green)
Fault/UID LED
(amber/blue)
Interpretation
Off Steadily amber A critical fault condition has been identified for this
drive, and the controller has placed it offline.
Replace the drive as soon as possible.
Off Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this
drive. Replace the drive as soon as possible.
Off Off The drive is offline, a spare, or not configured as
part of an array.
Hot-plug fan LED
Figure E-4: Hot-plug fan LED
Table E-6: Hot-plug fan LED
LED Status Description
Off Power is not applied to the fan
Green Power is applied to the fan and the fan is
functional
Amber Fan failure