Hp ProLiant DL585 Server User Manual Page 130

  • Download
  • Add to my manuals
  • Print
  • Page
    / 183
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 129
HP ProLiant DL585 Server User Guide C-1
C
System battery
The servers have memory devices that require a battery to retain stored information.
Battery replacement
When the server no longer automatically displays the correct date and time, you
might need to replace the battery that provides power to the real-time clock. Under
normal use, battery life is usually about five to 10 years. Use an HP 220-mAh
lithium, 3-V replacement battery.
To install a new battery:
1. Power down the server. Refer to “Powering down the server” in Chapter 2,
“Server operations.”
2. Extend the server from the rack. Refer to “Extending the server from the rack” in
Chapter 2, “Server operations.”
3. Remove the access panel. Refer to “Removing the access panel” in Chapter 2,
“Server operations.”
4. Locate the battery on the system board.
NOTE: It might be necessary to remove some PCI-X expansion boards to gain access to the
battery.
Page view 129
1 2 ... 125 126 127 128 129 130 131 132 133 134 135 ... 182 183

Comments to this Manuals

No comments