System LEDs and switches
E-4 HP ProLiant DL585 Server User Guide
Table E-3: Hot-plug SCSI hard drive LED combinations
Activity
LED
Online
LED
Fault
LED
Status
On Off Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
On Flashing Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing Flashing Flashing
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the
Array Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off Off Off OK to replace the drive online if a predictive failure
alert is received, and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
Off Off On OK to replace the drive online.
The drive has failed and has been placed off-line.
Off On Off OK to replace the drive online if a predictive failure
alert is received (refer to the following section for
details), provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
On or
flashing
On Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is online and being accessed.