HP EliteDesk 800 65W G3 Desktop Mini PC User Manual Page 107

  • Download
  • Add to my manuals
  • Print
  • Page
    / 139
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 106
Control panel message Description Recommended action
00E-Inventory Error during MEBx Execution BIOS information passed to the MEBx resulted
in a failure.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version.
3. If the error still persists, replace the
system board.
00F-Interface Error during MEBx Execution MEBx operation experienced a hardware error
during communication with the ME.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version.
3. If the error still persists, replace the
system board.
100-Front Audio Not Connected Front audio cable has been detached or
unseated from system board.
Reconnect or replace front audio cable.
2E1-MemorySize Error Memory amount has changed since the last
boot (memory added or removed).
The system memory size is dierent from the
last startup. The most common reason is the
removal of memory from the system board.
Press the F1 key to save the memory changes.
If this message persists, verify that the
memory modules are installed correctly.
2E2-Memory Error Memory module conguration failed during
boot up.
1. Ensure memory modules are correctly
installed.
2. Verify proper memory module type.
3. Remove and replace the identied faulty
memory module(s).
4. If the error persists after replacing
memory modules, replace the system
board.
2E3-Incompatible Memory Module in Memory
Socket(s) X, X, ...
A memory module in memory socket identied
in the error message is missing critical SPD
information, or is incompatible with the chipset.
1. Verify proper memory module type.
2. Try another memory socket.
3. Replace with a supported module.
2E4-DIMM Conguration Warning The current memory conguration is not
optimized.
Rearrange the DIMMs so that each channel has
the same amount of memory.
2E5-ECC Memory Module Detected on
Unsupported Platform
Recently added memory module(s) support ECC
memory error correction.
1. If additional memory was recently added,
remove it to see if the problem remains.
2. Check product documentation for
memory support information.
2E6–Memory Not Congured Correctly for
Proper MEBx Execution
DIMM1 is not installed. Make sure there is a memory module in the
DIMM1 socket and that it is properly seated.
300–Conguration Change Warning A change in storage conguration has been
detected (see Boot Options menu in BIOS Setup
to enable this feature). Either the installed
hardware has changed, storage or rmware
mode may have been changed, or a storage
device may have failed to respond.
If no changes have been made prior to this
warning, check that the drives are connected
properly to power cables and system board.
User Diagnostics (F2 during boot-up) may help
identify any problem with specic devices.
301-Hard Disk 1: SMART Hard Drive Detects
Imminent Failure
Hard drive is about to fail. (Some hard drives
have a hard drive rmware patch that will x an
erroneous error message.)
1. Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
POST numeric codes and text messages 99