Diagnostics B-11
LS - Image Sensor
W-LS-1 - Image Sensor Is Not Operat-
ing
The image sensor shutter cable is dis-
connected.
Connect the image sensor shutter
cable and restart the printer.
W-LS-2 - Image Sensor Is Not Operat-
ing
The image sensor cable is discon-
nected.
Connect the image sensor cable and
restart the printer.
MD - Media Drive
A-MD-1 - Media Advance Stalled The media drive motor has stalled. Check supply spool for binding, and
motor for failure.
(MS) Media Sensing
A-MS-3 - Media Too Far Left/Right Media is loaded too far to the left or
right.
Reload the media closer to the center
of the platen.
A-MS-4 - Media Out There is no media loaded. Load media.
A-MS-5 - Media Too Narrow Media loaded is not wide enough for
printing.
Load media that is at least 24 inches
wide.
W-MS-1 - Media Low Less than 10 feet (3 meters) of media
remains (roll-fed), or less than 1 foot
(30 cm) of media remains (sheet-
fed).
Monitor printing and reload media to
avoid running out of media during
printing.
W-MS-2 -
Media Non-Standard Width
Media loaded may cause head strike. Continue printing or replace media.
W-MS-4 -
Media Advance Switch Detected
Media Advance Switch on back of
printer was depressed.
Press the Load or Unload button on
the control panel to ensure proper
tensioning of the supply and takeup.
W-MS-6 -
Media Too Wide
Media loaded is too wide to be
printed on.
Replace media. See Appendix A,
Specifications, for supported widths.
(PC) Printing Calibrations
W-PC-2 - Media Replaced -
Recalibrate
Media advance accuracy may need to
be recalibrated.
Run Media Feed Calibration if media
type was changed (page 4-6).
W-PC-3 - Head Height Changed -
Recalibrate
Change in head height has invali-
dated calibration.
Run AutoSet (page 4-20).
W-PC-4 - Jets Not Replaced Not all missing jets could be replaced
in the current print mode.
Prime/clean printheads, or choose a
higher quality print mode (page 3-4).
W-PC-6 - Uncalibrated Pass Mode Print mode selected has media
advance rate different from the cali-
brated advance rate, which may
cause banding.
Run Media Feed Calibration
(page 4-6).
WC-PC-7 - Platen Width Not Known Measurement was reset or not per-
formed.
Restart printer to measure platen
width.
(SM) System
A-SM-1 - Printer Not Personalized Defective electronics assembly. Call Authorized Service Provider for
replacement electronics.
Table B-1. Actions and Warnings