Hp ProLiant DL320 G5p Server User Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
Hardware options installation 45
8.
Install the optional PCI-X riser board.
9. Install the expansion board ("Expansion board option" on page 42).
IMPORTANT: The server does not power up if the PCI riser board assembly is not seated
properly.
10. Install the PCI riser board assembly (on page 22).
11. Connect any internal cables for expansion boards.
12. Install the primary access panel.
13. Install the server into the rack.
Storage controller option
IMPORTANT: For additional installation and configuration information, refer to the
documentation that ships with the option.
To install the component:
1. Power down the server (on page 20).
2. Remove the server from the rack (on page 20).
3. Remove the primary access panel (on page 21).
4. Remove the PCI riser board assembly (on page 21).
5. Remove the hard drive cables.
6. Install the storage controller ("Expansion board option" on page 42).
IMPORTANT: The server does not power up if the PCI riser board assembly is not seated
properly.
7. Install the PCI riser board assembly (on page 22).
8. Connect the HP ProLiant DL320 hot-plug SAS/SATA cable, provided in the HP ProLiant DL320 hot-
plug cable option kit, to the SAS/SATA backplane.