Page view 139
2–78 edge switch 2/16 service manual
Diagnostics
33
The switch primitive sequence timed out (event code 585) or an invalid primitive
sequence was received for link state (event code 586). Either error causes the switch
to automatically reinitialize the fabric. Attached devices may momentarily logout, login,
and resume operation.
If the problem persists, an attached device may be marginally operating and causing
the error condition. Inform the customer of the problem.
34
A port was bypassed because a bit-error threshold was exceeded (event code 582).
If the problem persists, the attached device may be marginally operating and causing
the error condition. Inform the customer of the problem.
35
Does the embedded web server interface appear operational?
YES NO
Analysis for an Ethernet link, AC power distribution, or CTP card failure is not
described in this MAP. Go to "
MAP 0000: Start MAP
" on page 2-7. If this is the
second time at this step, contact the next level of support.
36
Inspect port operational states at the embedded web server interface.
a. At the View panel, click the Port Properties tab. The View panel (Port Properties
tab) displays.
b. Inspect the Operational State field.
c. At the View panel (Port Properties tab) click the first port (1).
d. Inspect the Operational State field.
e. At the View panel (Port Properties tab) sequentially click the remaining ports.
Inspect the Operational State field for each port.
Does the Operational State field display a Segmented message for a port?
NO YES
Port segmentation is indicated. Go to "
MAP 0700: Fabric, ISL, and Segmented
Port Problem Determination
" on page 2-79.