3–22 edge switch 2/16 service manual
Repair Information
LIN Alerts Configuration - a user-specified state for the port (On or Off),
configured through the Configure Ports dialog box.
Beaconing - user-specified for the port (On or Off). When beaconing is enabled, a
yellow triangle appears adjacent to the status field.
Link Incident - If no link incidents are recorded, None appears in the status field.
If a link incident is recorded, a summary appears describing the incident, and a
yellow triangle appears adjacent to the status field. Valid summaries are:
Implicit incident.
Bit-error threshold exceeded.
Link failure - loss of signal or loss of synchronization.
Link failure - not-operational primitive sequence received.
Link failure - primitive sequence timeout.
Link failure - invalid primitive sequence received for the current link state.
Operational State - the state of the port (Online, Offline, Beaconing, Invalid
Attachment, Link Incident, Link Reset, No Light, Not Operational, Port Failure,
Segmented E_Port, or Testing). A yellow triangle appears adjacent to the status
field if the port is in a non-standard state that requires attention. A red and yellow
diamond appears adjacent to the status field if the port fails.
Reason - If the E_Port segments while attempting to form a multi-switch fabric, a
summary appears describing the reason for segmentation. Valid summaries are:
Incompatible operating parameters.
Duplicate domain ID(s).
Incompatible zoning configurations.
Build fabric protocol error.
No principal switch.
No response from attached switch.
Exchange link protocol (ELP) retransmission failure timeout.
This field also displays reasons for Invalid Attachment state:
01 Unknown. Invalid attachment reason cannot be determined.
02 ISL connection not allowed on this port. Port is configured as an F_Port, but
connected to switch or director.