edge switch 2/16 service manual 3–37
Repair Information
4. Click Yes to IPL the switch. During the IPL, the switch-to-HAFM server Ethernet
link drops momentarily and the following occur at the product manager
application:
As the network connection drops, the Status table turns yellow, the Status
field displays No Link, and the State field displays a reason message.
The alert panel at the bottom of the navigation control panel displays a grey
square, indicating switch status is unknown.
Illustrated FRUs (SFPs, fans, and power supplies) in the Hardware View
disappear, and appear again as the connection is re-established.
Set the Switch Online or Offline
This section describes procedures to set the switch online or offline. These operating
states are described as follows:
Online - when the switch is set online, an attached device can log in to the switch
if the port is not blocked. Attached devices can communicate with each other if
they are configured in the same zone.
Offline - when the switch is set offline, all switch ports are set offline. The switch
transmits the offline sequence (OLS) to attached devices, and the devices cannot
log in to the switch.
NOTE: When the switch is set offline, the operation of attached Fibre Channel devices is
disrupted. Do not set the switch offline unless directed to do so by a procedural step or the next
level of support.
Set Online State
To set the switch online:
1. At the HAFM server, open the HAFM application. The Product View displays.
2. Select the icon representing the switch to be set online. The Hardware View for the
selected switch displays.