edge switch 2/16 service manual 2–1
2
Diagnostics
This chapter describes diagnostic procedures used by service representatives to isolate
hp StorageWorks edge switch 2/16 (edge switch 2/16) problems or failures to the
field-replaceable unit (FRU) level. The chapter specifically describes how to perform
maintenance analysis procedures (MAPs).
Maintenance Analysis Procedures
The MAPs provide fault isolation and related service procedures. They are
step-by-step procedures that prompt service personnel for information and describe a
maintenance action. They provide information to interpret system events, isolate a
switch failure to a single FRU, remove and replace the failed FRU, and verify switch
operation.
Factory Defaults
Table 2–1 lists the defaults for the passwords, and IP, subnet, and gateway addresses.
Quick Start
Table 2–2 lists the MAPs in this chapter. Fault isolation normally begins at "MAP 0000:
Start MAP
" on page 2-7.
Table 2–1: Factory-Set Defaults
Item Default
Customer password password
Maintenance password level-2
IP address 10.1.1.10
Subnet mask 255.0.0.0
Gateway address 0.0.0.0