Page view 124
edge switch 2/16 service manual 2–63
Diagnostics
14
The SBAR on the CTP card failed. Because the SBAR is not a FRU, SBAR failure
requires replacing the switch.
Contact the next level of support.
MAP 0600: Port Failure and Link Incident Analysis
This MAP describes fault isolation for small form factor pluggable (SFP) transceivers
and Fibre Channel link incidents. Failure indicators include:
The amber LED adjacent to a Fibre Channel port illuminates.
The amber emulated LED adjacent to a port graphic at the Hardware View
illuminates.
A blinking red and yellow diamond (failed FRU indicator) or yellow triangle
(attention indicator) appears at the Product View or Hardware View.
An event code recorded at the switch Event Log or the embedded web server event
log.
A port failure message at the Port Properties dialog box or embedded web server
interface.
A link incident message at the Link Incident Log or Port Properties.
1
Was an event code 080, 440, 504, 506, 507, 508, 512, 514, or 604 observed at the
switch Event Log (HAFM server) or at the embedded web server event log?
NO YES
Go to step 3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the console of an OSI
or FICON server attached to the switch reporting the problem.?
YES NO
Go to step 4.