HP AA-RS2JA-TE User Manual Page 172

  • Download
  • Add to my manuals
  • Print
  • Page
    / 360
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 171
3–16 edge switch 2/16 service manual
Repair Information
THM - thermal sensor. The chassis slot is 0 (on the CTP card). The thermal
sensor is not a FRU.
Position-a number representing the FRU chassis position. The chassis (slot)
position for a nonredundant FRU is 0. The chassis positions for redundant FRUs
are 0 and 1.
Status-the FRU status (Active or Backup).
Part Number-the FRU part number.
Serial Number-the FRU serial number.
Node List View
The Node List View (Figure 3–9) displays information about all devices attached to
the switch through node ports (N_Ports). The information is useful to maintenance
personnel for fault isolation and repair verification.
To open the Node List View, select Node List from the View menu on the navigation
control panel.
Figure 3–9: Node List View
The Node List View contains the following columns:
Port # - the port number (0 through 15). Only ports attached to a device are
displayed.
Page view 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 359 360

Comments to this Manuals

No comments