2–70 edge switch 2/16 service manual
Diagnostics
The switch appears operational.
Go to step 4.
16
The port has an invalid attachment. The information in the Port Properties dialog box
specifies the reason as listed in the following table.
17
The port connection conflicts with the configured port type. Either an
expansion port (E_Port) is incorrectly cabled to a Fibre Channel device or a
fabric port (F_Port) is incorrectly cabled to a fabric element (director or switch).
a. At the HAFM server’s Hardware View, click the Configure icon at the navigation
control panel and select Ports from the Configure menu. The Configure Ports
dialog box (open systems mode) displays.
Reason Action
Unknown Contact the next
level of support.
ISL connection not allowed on
this port.
Go to step 17.
Incompatible switch at other end
of ISL.
Go to step 18.
External loopback adapter
connected to the port.
Go to step 19.
N-Port connection not allowed
on this port.
Go to step 17.
Non-Hewlett Packard switch at
other end of the ISL.
Go to step 18.
Port binding violation -
Unauthorized WWN.
Go to step 21.
Unresponsive node connected
to port.
Go to step 22.