Hp XP P9500 Storage User Manual Page 83

  • Download
  • Add to my manuals
  • Print
  • Page
    / 192
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 82
Forward Path Watch Time—establishes whether to forward the Path Watch Time value of the
master journal to the restore journal.
Transfer Speed—which specifies the speed for data transfer
Delta Resync Failure—which specifies the processing that takes place in the event of a failure.
Prerequisite information
Please be aware of the following when changing mirror options:
Mirror options can be changed on both primary and secondary systems.
To change mirror options, the status of the mirror must be one of the following:
Initial
Active
Stopped
Hold
Holding
Hold(Failure)
The Transfer Speed option can be changed if the mirror’s status is Active, Hold, or Holding.
When changing options for multiple mirrors, you can leave some options unchanged by
entering or selecting no value. If you specify a value, it is applied to the selected mirrors.
Procedure 20 To change options for a mirror
1. In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal > Journal Operation. The Journal Operation window displays.
2. Click to change the mode from View to Modify.
3. In the table pane, right-click the desired journal and then select Mirror > Change Mirror Option.
4. For Unit of Path Watch Time, specify the unit of time for Path Watch Time, minute, hour, or
day.
Journal and mirror maintenance 83
Page view 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 191 192

Comments to this Manuals

No comments