Hp XP P9500 Storage User Manual Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 192
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
11. In the DKC Option dialog box, Minimum Paths is intended for a future release. Continue to
the next step.
12. In the RIO MIH Time box, enter the time interval in seconds that, if exceeded, will cause the
data transfer operation to be reported as failed by the system. Valid values range from 10
seconds to 100 seconds, and the default is 15 seconds.
RIO MIH means “remote I/O missing interrupt handler”.
NOTE: The recommended RIO MIH setting for a 3DC cascade configuration is 20 seconds.
13. Click Set.
To change a path, right-click it in the Preview list and select Modify. Make any changes
in the Add Path dialog box then click Set.
To delete an added logical path, right-click the path in the Preview list and select Delete.
14. Click Apply to save the configuration.
Configuring additional logical paths
You can configure additional logical paths as needed. A maximum of eight logical paths are
supported.
Prerequisite information
Review the prerequisites for configuring logical paths in “Configuring local and remote systems
for Cnt Ac-J ” (page 45).
Procedure 3 To configure additional logical paths
1. In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal > DKC Operation.
2. Click to change the mode from View to Modify.
3. In the tree, select the remote system. The logical paths display in the full right-side list.
4. Right-click a logical path, and select Add Path from the menu.
5. In the M-R Path box, define the fibre-channel port used by the logical path between local and
remote systems:
48 Configuration operations
Page view 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 191 192

Comments to this Manuals

No comments