2. Click to change the mode from View to Modify.
3. In the Display box, select Port.
4. In the list of ports, right-click the port that you want to change and select the desired port type:
Initiator, RCU Target, or Target).
5. When you are finished defining ports, review the Preview list.
To change a setting, right-click the port in and select the attribute.
To delete a setting, right-click the port and select Delete.
6. Click Apply to save your modifications in the system.
Configuring local and remote systems for Cnt Ac-J
You associate the primary and secondary systems in the Continuous Access Journal relationship
and define the logical paths between them in one procedure.
Prerequisite information
This procedure must be performed on both primary and secondary systems
The primary and secondary systems must already be configured for Continuous Access Journal
operations. See “System requirements” (page 15) for more information.
The data path must be set up. See “Planning the data path” (page 34) for more information.
The port attributes on the primary and secondary systems must be configured for Cnt Ac-J.
See “Defining fibre-channel port attributes ” (page 44).
Configuring local and remote systems for Cnt Ac-J 45