Hp XP P9500 Storage User Manual Page 113

  • Download
  • Add to my manuals
  • Print
  • Page
    / 192
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 112
DescriptionError code (SSB2)
A request of Cnt Ac-J Paircreate on the Cnt Ac-J intermediate volume was rejected because either
Cnt Ac-J Z or Cnt Ac-S Z was not installed.
B90F
The settings of the journal option could not be updated.B910
The command was rejected because the system configuration does not allow these operations.B913
The command was rejected because no journal was registered.B912/B9F8
A request of Cnt Ac-J pair status transition was rejected because the status for the request could
not be transited. (ex. Status transition other than SMPL when the Paircreate was requested, or
other than PSUS when the Pairresync was requested.)
DB02
A request of Cnt Ac-J Pair status transition was rejected because the pair was in the state of
Suspending or Deleting.
DB03
Cnt Ac-J pair status cannot be transited during the power-on processing.DB07
Cnt Ac-J pair status cannot be transited during the power-off processing.DB08
The command was rejected because the specification was volume instead of group.DB0C
The command was rejected because the CLPR number of the specified volume differed from the
CLPR number of the journal.
E843
The command was rejected because the specified volume belongs to the journal that is contained
in the Cnt Ac-J-Continuous Access Synchronous combination (2DC) configuration in the intermediate
site.
E846
An operation request for the journal, which was used in the system that consists of single primary
and secondary system, was rejected because the specified volume is defined to be used in the
system that consists of multiple primary and secondary systems.
E847
An operation request for the journal, which was used in the system that consists of multiple primary
and secondary systems, was rejected because the specified volume is defined to be used in the
system that consists of single primary and secondary system.
E848
The specified consistency group number is already used.E866
The operation cannot be performed because the specified restore journal was used in another
mirror and the mirror status was Halting or Stopping. Retry the operation after the mirror status
is changed to a status other than Halting or Stopping
E869
The command was rejected because the path between the storage devices for the both-way was
not defined. Check whether the bidirectional normal path was defined or not.
E871
The command was rejected because the data volumes of 3390-9A and other than 3390-9A
coexist in the specified journal.
E878
The command was rejected because the specified journal was unregistered.E87B
Journal volume is not registered in the specified journal.E87C
The command was rejected because the specified volume was not for the Cnt Ac-J pair.E87D
The command was rejected because the specified P-VOL or S-VOL was a journal volume.E87E
The command was rejected because the emulation type was different between the specified
P-VOL or S-VOL and the journal volume.
E880
The command was rejected because of the power-on processing.E881
The command was rejected because the emulation type of the specified master journal or the
restore journal was invalid.
E882
The specified mirror ID number or the CTG number differs from the registered mirror ID number
or the CTG number.
E883
The command was rejected because the specified master journal was already used for a pair
with another restore journal.
E888
Troubleshooting with RAID Manager 113
Page view 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 191 192

Comments to this Manuals

No comments