Datasheet, Volume 1 67
Thermal Management
Table 5-1. Intel
®
Turbo Boost Technology Package Power Control Settings
MSR:
Address:
MSR_TURBO_POWER_LIMIT
610h
Control Bit Default Description
POWER_LIMIT_1 (PL1) 14:0 SKU TDP
This value sets the exponentially weighted moving
average power limit over a long time period. This is
normally aligned to the TDP of the part and steady-
state cooling capability of the thermal solution. This
limit may be set lower than TDP, real-time, for specific
needs such as responding to a thermal event. If set
lower than TDP, the processor may not be able to honor
this limit for all workloads since this control only applies
in the Turbo frequency range; a very high powered
application may exceed POWER_LIMIT_1, even at non-
Turbo frequencies. PL1 limit may be set slightly higher
than TDP. If set higher than TDP, the processor could
stay at that power level continuously and cooling
solution improvements may be required.
POWER_LIMIT_1_TIME
(Turbo Time Parameter)
23:17 1 sec
This value is a time parameter that adjusts the
algorithm behavior. The exponentially weighted moving
average Turbo algorithm will use this parameter to
maintain time averaged power at or below
POWER_LIMIT_1. The default value is 1 second, but
28 seconds is recommended for most mobile
applications.
POWER_LIMIT_2 (PL2) 46:32 1.25 x TDP
Establishes the upper power limit of Turbo operation
above TDP, primarily for platform power supply
considerations. Power may exceed this limit for up to
10 ms. The default for this limit is 1.25 x nominal TDP.
Setting this limit to TDP will limit the processor to only
operating up to TDP, but it does not disable Turbo.
Because Turbo is opportunistic and power/temperature
dependant, many workloads will allow some Turbo
frequencies at power at or below TDP.
Figure 5-1. Package Power Control
System Thermal Response Time
System Thermal Response Time