Figure 73 BIOS Serial Console and EMS BIOS Serial Console Baud Rate screen
Setting the EMS Console
You can configure the ACPI serial port settings, which can be used to configure the Windows
Server Emergency Management (EMS) console to be redirected through a serial port.
When making this selection for redirecting EMS through a network connection, there are two
options:
If using iLO 4, select the value (COM 1 or COM2) that corresponds to the resources assigned
to the Virtual Serial Port in the Systems option menu.
If redirecting EMS through a physical serial port, select the value (COM1 or COM2) that
corresponds to the resources assigned to the Embedded Serial Ports in the System Options
menu.
To set the EMS Console:
1. From the System Utilities screen, select System ConfigurationBIOS/Platform Configuration
(RBSU)BIOS Serial Console and EMS and select EMS Console and press Enter.
2. Select one of the following options:
Disabled (default)
COM1
COM2
3. Press F10 to save your selection.
82 Accessing the System Configuration Menu