Page view 58
Figure 49 Server Availability ASR Timeout screen
Setting Thermal Shutdown
Initiate a shutdown due to non-redundant fan failures or temperature increases beyond the pre-set
threshold. If disabled, the System Management Driver ignores thermal events and the system
immediately powers off in data-destructive situations.
To set thermal shutdown:
1. From the System Utilities screen, select System ConfigurationBIOS/Platform Configuration
(RBSU)Server Availability and select Thermal Shutdown and press Enter.
2. Select one of the following options:
Enabled—Allows the Advanced System Management Driver to initiate a system shutdown
when the temperature reaches within 5 degrees of critical level.
Disabled (default)—Allows the Advanced System Management Driver to shut down the
system at critical level.
3. Press F10 to save your selection.