ii
Max. Continuous
Baking Time
5 seconds 5 seconds 15 seconds Controlled by Braking Unit
5
Max. Duty 3 % ED 2 % ED 5 % ED 5 % ED
Weight [lbs] 10.4 10.4 10.6 10.8 17.0 17.0 30.6 31.7 44.1 44.1
460V Class (40 ~ 100HP)
Model Number
SV xxx ACtionMaster - 4
300 370 450 550 750
HP
40 50 60 75 100
Motor
Rating
1
kW
30 37 45 55 75
Capacity
2
[kVA]
45 56 68 82 100
FLA [A]
61 75 91 110 152
Frequency 0 ~ 400 Hz (0-120Hz for Vector control)
Output
Ratings
Voltage 380 ~ 460 V
3
Voltage 3 Phase, 380 ~ 460 V (± 10 %) Input
Ratings
Frequency 50 ~ 60 Hz (±5 %)
Braking Circuit Optional (Braking Unit, Resistor)
4
Max. Braking Torque 150%
Max. Continuous
Baking Time
Controlled by Braking Unit
5
Dynamic
Braking
4
Max. Duty 5 % ED
Weight [lbs] 45 45 63 63 68
Common Features Specification
Control Method V/F Control,
Sensorless Vector Control (Speed/Torque), Sensored Vector Control (Speed/Torque) Selectable
Frequency Setting
Resolution
Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz)
Analog Reference: 0.03 Hz / 60 Hz
Frequency Accuracy Digital: 0.01 % of Max. Output Frequency
Analog: 0.1 % of Max. Output Frequency
V/F Ratio Linear, Square Pattern, User V/F
Overload Capacity 150 % of Rated Current for 1 Min., 200% of Rated Current for 0.5 sec. (Characteristic is Inversely
Proportional to Time)
CONTROL
Torque Boost Manual Torque Boost (0 ~ 20 %), Auto Torque Boost
Operation Method Key / Terminal / Communication Operation
Frequency Setting Analog: 0 ~ 10V / 4 ~ 20mA / Additional ports (VR: +12V, 10mA, V2: 0-10V) for Sub-Boards
Digital: Keypad
Start Signal Forward, Reverse
Multi-Step Up to 8 Speeds can be Set (Use Multi-Function Terminal)
Multi Step
Accel/Decel Time
0 ~ 6,000 sec, Up to 4 Types can be Set and Selectable for Each Setting (Use Multi- Function
Terminal)
Accel/Decel Pattern: Linear, U-Curve, S-Curve Selectable
OPERATION
Input Signal
Emergency Stop Instantly Interrupts the Inverter Output
5
Refer to Chapter 7 Options for DBU and DB Resistors