Chapter 5 - Parameter List
5-4
Keypad Display Setting Range
Code Description
LCD 7-Segment LCD 7-Segment
Units
Factory
Default
Adj.
During
Run
Page
FU1-25 High Limit Frequency
F-limit Hi
25 FU1-24 to FU1-20 0.01 60.00 [Hz] No
Manual 0
FU1-26
Manual/Auto Torque
Boost Selection
Torque boost
26
Auto 1
- Manual No 6-2
FU1-27
Torque Boost in Forward
Direction
Fwd boost
27 0 to 15 [%] 0.1 2.0 [%] No
FU1-28
Torque Boost in Reverse
Direction
Rev boost
28 0 to 15 [%] 0.1 2.0 [%] No
6-2
Linear 0
Square 1
FU1-29 Volts/Hz Pattern
V/F pattern
29
User V/F 2
- Linear No 6-2
FU1-30
15
User V/F – Frequency 1
User freq 1
30 0 to FU1-20 0.01 15.00 [Hz] No
FU1-31 User V/F – Voltage 1
User volt 1
31 0 to 100 [%] 1 25 [%] No
FU1-32 User V/F – Frequency 2
User freq 2
32 0 to FU1-20 0.01 30.00 [Hz] No
FU1-33 User V/F – Voltage 2
User volt 2
33 0 to 100 [%] 1 50 [%] No
FU1-34 User V/F – Frequency 3
User freq 3
34 0 to FU1-20 0.01 45.00 [Hz] No
FU1-35 User V/F – Voltage 3
User volt 3
35 0 to 100 [%] 1 75 [%] No
FU1-36 User V/F – Frequency 4
User freq 4
36 0 to FU1-20 0.01 60.00 [Hz] No
FU1-37 User V/F – Voltage 4
User volt 4
37 0 to 100 [%] 1 100 [%] No
6-2
FU1-38
Output Voltage
Adjustment
Volt control
38 40 to 110 [%] 0.1 100.0 [%] No 6-2
FU1-39 Energy Save Level
Energy save
39 0 to 30 [%] 1 0 [%] Yes 6-2
No 0
FU1-50
Electronic Thermal
Selection
ETH select
50
Yes 1
- No Yes
FU1-51
16
Electronic Thermal Level
for 1 Minute
ETH 1 min
51 FU1-52 to 200 [%] 1 150 [%] Yes
FU1-52
Electronic Thermal Level
for Continuous
ETH cont
52 50 to FU1-51 1 100 [%] Yes
Self-cool 0
FU1-53
Electronic Thermal
Characteristic Selection
(Motor Type)
Motor type
53
Forced-cool 1
- Self-cool Yes
6-2
FU1-54 Overload Warning Level
OL level
54 30 to 150 [%] 1 150 [%] Yes
FU1-55
Overload Warning Hold
Time
OL time
55 0 to 30 [sec] 0.1 10.0 [sec] Yes
6-2
No 0
FU1-56 Overload Trip Selection
OLT select
56
Yes 1
- Yes Yes
FU1-57 Overload Trip Level
OLT level
57 30 to 150 [%] 1 180 [%] Yes
FU1-58 Overload Trip Delay Time
OLT time
58 0 to 60 [sec] 1 60.0 [sec] Yes
6-2
FU1-59
Stall Prevention Mode
Selection
Stall prev.
59
000 to 111
(Bit Set)
bit 000 No
FU1-60 Stall Prevention Level
Stall level
60 30 to 250 [%] 1 180 [%] No
6-2
15
Code FU1-30 through FU1-37 appears only when FU1-29 is set to ‘User V/F’.
16
Code FU1-51 through FU1-53 appears only when FU1-50 is set to ‘Yes’.