HP HSR6600 Installation Manual Page 59

  • Download
  • Add to my manuals
  • Print
  • Page
    / 107
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 58
53
Table 14 Output description
Field Descri
p
tion
System Total Memory(bytes) Physical memory size (in bytes) of the module
Total Used Memory(bytes) Used memory size (in bytes) of the module
Used Rate Memory usage of the module
Displaying the CF card information
Use the display device cf-card command to display the CF card information.
<Sysname> display device cf-card
Slot No. Dev No. Status Size(M)
-----------------------------------------------
0 0 Normal 495
0 1 Absent N/A
Table 15 Output description
Field Descri
p
tion
Slot No Slot number of the CF card
Dev No.
Device number of the CF card:
0 for a built-in CF card
1 for an external CF card
Status:
Operational status of the CF card:
Absent—No CF card is present in the slot.
Fault—The CF card fails.
Normal—The CF card is operating properly.
Size (M) Storage capacity of the CF card
Displaying the operational status of the built-in fan
Use the display fan command to display the operational status of the built-in fan.
<Sysname> display fan
Fan 1 State: Normal
Table 16 Output description
Field Descri
p
tion
Fan 1 Number of the fan
State
The fan state:
Normal—The fan is operating properly.
Absent—The fan is not in position.
Fault—The fan fails.
Page view 58