HP Integrity rx1620 Maintenance Guide
HP Part Number: AB430-96014
Published: January 2012
Edition: 3
Page view 0
1 2 3 4 5 6 ... 72 73

Summary of Contents

Page 1 - Edition: 3

HP Integrity rx1620 Maintenance GuideHP Part Number: AB430-96014Published: January 2012Edition: 3

Page 2

Installing Processors and MemoryThis section provides information about installing processors and memory. The processors andmemory slots are located o

Page 3 - Contents

Figure 4 Processor Location1. Remove the cover. See “Removing and Replacing the Cover” (page 30).2. Remove the sheet metal air duct by pulling it stra

Page 4 - 4 Contents

Figure 5 Removing the Airflow Blocker, CPU Dust Cover, and Air Duct5. Unlock the processor-locking mechanism using the special processor tool (P/N 506

Page 5 - 1 About This Document

Figure 6 Unlocking the Processor Locking Mechanism6. Remove the pin cover and protective caps for the captive screws on the processor.7. Place the pro

Page 6 - Where to Get Help

8. Use the special processor tool (P/N 5069-5441) shipped with your replacement processorassembly to lock the processor in place on the system board.

Page 7 - 2 Installing and Configuring

Figure 10 Connecting the Processor Power Pod11. Align the two mounting screw holes on the power module with their screw holes on the systemboard’s met

Page 8 - 8 Installing and Configuring

Figure 11 Securing the Processor Power Pod12. Connect the power pod cable to the power connector on the system board.16 Installing and Configuring

Page 9

Figure 12 Connecting the Power Cable13. Reinstall the sheet metal air duct.14. Replace the cover.15. Verify that the newly installed processor works:•

Page 10

Figure 13 DIMM Loading OrderDIMM LocationsEight DIMM slots are provided on the system board. These DIMM slots are designated in orderedpairs. 0A and 0

Page 11

Figure 14 DIMM LocationsInstalling DIMMsTo install DIMMs, perform the following steps:Installing Additional Memory 19

Page 12 - 12 Installing and Configuring

© Copyright 2005, 2012 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice. The only warrant

Page 13

1. Turn off the system, disconnect all cables, and remove the system cover.CAUTION: To ensure that memory modules are not damaged during removal or in

Page 14 - 14 Installing and Configuring

6. Replace the cover, reconnect all cables, and turn on the power.7. Verify that the newly installed memory works:• Run the info mem command at the EF

Page 15

Figure 16 Using Jackscrew to Release PCI I/O Riser3. Remove the PCI I/O Riser from the chassis.22 Installing and Configuring

Page 16 - 16 Installing and Configuring

Figure 17 Removing the PCI I/O Riser Assembly4. Remove the PCI slot cover.Figure 18 Removing a PCI Slot Cover5. Grasp the edges of the PCI card being

Page 17 - Installing Additional Memory

Figure 19 Installing a PCI Card6. Insert the card mounting screw and secure with a T-15 driver.7. Replace the PCI I/O riser assembly by positioning th

Page 18 - DIMM Locations

Figure 20 Removing the MP Card Blank5. Remove the insulator between the battery and the battery socket on the management processorcard.6. Align the MP

Page 19 - Installing DIMMs

Figure 21 Connecting the Management Processor Card10. Screw in the two external mounting posts that are located on both sides of the 25-pin serialconn

Page 20 - 20 Installing and Configuring

Figure 22 Installing the External Mounting Posts11. Replace the system cover and reconnect the power and external cables.Information required to acces

Page 21 - Installing a PCI Card

3 Removing and Replacing ComponentsThis chapter provides instructions for removing and replacing components of the HP Integrity rx1620Server.Safety In

Page 22 - 22 Installing and Configuring

Insert the Server into the RackTo insert the server into the rack, perform the following steps:1. Press the rail clips on either side of the server in

Page 23

Contents1 About This Document...5What’s in This Document...

Page 24 - 24 Installing and Configuring

Removing and Replacing the CoverCAUTION: Do not operate the server without the cover in place. Operation of the server withoutthe cover in place will

Page 25

1. Align the tabs on the cover with the slots on the sides of the chassis.Figure 25 Aligning the Cover2. Close the cover by moving the latch handle cl

Page 26 - 26 Installing and Configuring

Removing and Replacing System MemorySystem memory DIMMs are located on the system board.WARNING! Ensure that the system is powered-down and all power

Page 27

Installing System MemoryTo install DIMMs, perform the following steps:1. Align the DIMM with the socket located on the system board.2. Gently and even

Page 28 - Service Tools Required

Figure 29 Processor LocationWARNING! Ensure that the system is powered-down and all power sources have beendisconnected from the server prior to remov

Page 29 - Replacing the Front Bezel

Figure 305. Remove the two power pod mounting screws.Figure 31 Remove the Processor Power Pod Mounting ScrewsRemoving and Replacing a Processor 35

Page 30 - Replacing the Cover

6. Disconnect the power pod by sliding the power pod toward the rear of the system board.Figure 32 Disconnecting the Processor Power Pod7. Lift the po

Page 31 - Figure 26 Closing the Cover

Figure 33 Removing the Power Pod8. Release the four captive screws on the processor.9. Unlock the processor-locking mechanism using the special proces

Page 32 - Removing System Memory

Figure 34 Unlock the Processor Socket38 Removing and Replacing Components

Page 33 - Installing System Memory

10. Lift the processor up and out of the chassis. Place the processor into an antistatic container.Figure 35 Removing the ProcessorReplacing a Process

Page 34 - Removing a Processor

Removing and Replacing the PCI I/O Riser Assembly...50Removing the PCI I/O Riser Assemb

Page 35 - Figure 30

1. Turn off the system and disconnect all cables.2. Remove the cover. See “Removing and Replacing the Cover” (page 30).3. Unlock the processor-locking

Page 36

Figure 37 Locking the Processor Assembly in Place6. Use the special processor tool shipped with your replacement processor assembly to lock theprocess

Page 37

Figure 39 Installing the Processor8. Slide the power module on the system board metal mounting bracket so that the power modulecontacts connect with t

Page 38

Figure 41 Securing the Processor Power Pod10. Connect the power pod cable to the power connector on the system board.Removing and Replacing a Processo

Page 39 - Replacing a Processor

Figure 42 Connecting the Power Cable11. Reinstall the sheet metal air duct.12. Replace the cover.13. Verify that the newly installed processor works:•

Page 40

3. Lift up on the battery and push on the back of it with a flat-head screwdriver to remove thebattery from its holder.Figure 43 Removing the System B

Page 41

5. You may need to reset the system time and date using the EFI time and date commands. Onceyou have set the time, turn the system off, unplug the pow

Page 42

Replacing the Power Supply Fan UnitTo replace a power supply fan unit, perform the following steps:1. Orient the power supply fan unit by aligning the

Page 43

3. Check the front panel diagnostic LEDs for indication of the replaced fan unit.• When the fan is functioning normally, the LED is off.• When the fan

Page 44 - Removing the System Battery

Replacing the Display PanelTo replace the display panel, perform the following steps:1. Place the display panel over the stand-offs on the chassis.2.

Page 45 - Replacing the System Battery

1 About This DocumentThis document describes how to maintain your HP Integrity rx1620 Server, Regulatory ModelNumber: RSVLA-0406.The document printing

Page 46

Removing and Replacing the PCI I/O Riser AssemblyThe server may contain up to 2 PCI cards. PCI cards are located on the PCI I/O riser assembly.WARNING

Page 47 - Replacing a Chassis Fan Unit

Figure 47 Using Jackscrew to Release PCI I/O Riser4. Lift the PCI I/O riser assembly up and away from the chassis. Place the removed PCI I/O riserasse

Page 48 - Removing the Display Panel

Figure 48 Removing the I/O Riser Assembly5. Replace the cover. See “Removing and Replacing the Cover” (page 30).Replacing the PCI I/O Riser Assembly1.

Page 49 - Replacing the Display Panel

Removing and Replacing PCI CardsThe server may contain up to 2 PCI cards. PCI cards are located on the PCI I/O riser assembly.WARNING! Ensure that the

Page 50

Figure 49 Using Jackscrew to Release PCI I/O Riser4. Grasp the edges of the PCI card being removed and gently rock the card releasing theconnector fro

Page 51

7. Replace the cover. See “Removing and Replacing the Cover” (page 30).Figure 50 Removing the I/O Riser AssemblyFigure 51 Removing a PCI Slot CoverRep

Page 52

3. Release the PCI I/O riser by lifting the release handle. This action frees the PCI I/O riser fromthe system board.4. Grasp the edges of the PCI car

Page 53 - Removing a PCI Card

Figure 53 Removing an Internal Hard Disk Drive3. Place the removed drive in an antistatic container.4. If a replacement disk drive is not being instal

Page 54

1. If installing an additional drive, remove the slot filler that is installed in slot 1. If replacing adisk drive, the slot will be empty due to the

Page 55 - Replacing a PCI Card

Figure 554. The disk drive is now correctly installed.Removing and Replacing the Power SupplyThe power supply is located at the left front of the serv

Page 56

IMPORTANT: The latest version of this document can be found online at http://www.hp.com/bizsupport.HP Encourages Your CommentsHP encourages your comme

Page 57

Figure 56 Power Supply Removal/Replacement4. Carefully lift the power supply cable free from all retaining clips.5. At the rear of the chassis, remove

Page 58

Figure 57 Power Supply Cable6. Replace the power supply fan unit into the chassis.7. Replace the cover.Removing and Replacing a Removable Media DriveT

Page 59 - Removing the Power Supply

Removing a Removable Media DriveTo remove a removable media drive, perform the following steps:1. Turn off the system and disconnect all cables.2. Rem

Page 60 - Replacing the Power Supply

5. Pull the drive straight forward approximately 3/4” to release the drive from the tab on thechassis, then lift up and out to remove the drive from t

Page 61

5. Connect the MP card:a. Connect the MP card cable to its connector on the system board.b. Screw in the two mounting screws that connect the MP card

Page 62

Figure 61 Installing the External Mounting Posts7. Replace the system cover(s) and reconnect the power and external cables.Information required to acc

Page 63

Figure 62 Location of Management Processor Battery3. Lift up on the battery and push on the back of it with a flat-head screwdriver to remove thebatte

Page 64

1. Remove the following components from your existing base unit. Refer to earlier sections of thischapter for component removal and replacement instru

Page 65

• Management Processor Blank (present when Management Processor not installed)• PCI I/O Backplane Assembly• CPU(s) and associated Power Pods• CPU Airf

Page 66 - Replacing the Base Unit

4 Parts InformationField Replaceable Parts (FRU) ListThis chapter provides parts information for the field replaceable units (FRUs) of the HP Integrit

Page 67 - Replacing the Base Unit 67

2 Installing and ConfiguringThis chapter provides information required in installing additional components and configuringthe HP Integrity rx1620 Serv

Page 68

Figure 65 Additional ComponentsThe items in this list apply to the HP Integrity rx1620 Server, except where noted.70 Parts Information

Page 69 - 4 Parts Information

NOTE: Part numbers are found by using the part nomenclature from this list to select the correctpart from the HP Partsurfer. If a part that is not lis

Page 70 - 70 Parts Information

Table 1 Field Replaceable Parts (FRU) List (continued)Part NumberExchangePart NumberReplacementDescriptionItem No.AB430-04001Sheet Metal Air Duct13AB4

Page 71

IndexAanti-static wrist strap, 28Bbase unitreplacing, 66Ccoverremoving and replacing, 30Ddisplay panelremoving and replacing, 48Ffan unitsremoving and

Page 72

1. Remove the slot filler that is installed in slot 1.CAUTION: If the HP Server is to be operated with only a single hard disk drive installed,the har

Page 73

Figure 3 Disk Drive Installation in Slot 13. Close the drive-ejector handle by pushing it down until it clicks.4. The hard disk drive is now correctly