ProLiant ML530 ServersMaintenance and Service GuideFourth Edition (September 2000)Part Number 122829-004Spare Part Number 159306-001Compaq Computer Co
Chapter 1Illustrated Parts ListThis chapter provides the illustrated parts breakdown and a spare parts list for CompaqProLiant™ ML530 servers. To obt
3-40 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionAcc
Diagnostics and Troubleshooting 3-41Table 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionAcceleratorstatus: Valid datafo
3-42 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionCon
Diagnostics and Troubleshooting 3-43Table 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionDrive (bay) X is areplacementdr
3-44 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionErr
Diagnostics and Troubleshooting 3-45Table 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionLogical Drive Xstatus = FAILEDT
3-46 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionLoo
Diagnostics and Troubleshooting 3-47Table 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionProLiant storageunit on SCSIbus
3-48 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionSCS
Diagnostics and Troubleshooting 3-49Table 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionSystem board isunable to identi
1-2 Compaq ProLiant ML530 Servers Maintenance and Service GuideExternal Components—Exploded View2b176920a54112a3810Figure 1-1. External components—
3-50 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-20ADU Diagnostic Messages continuedMessage Description Recommended ActionWar
Diagnostics and Troubleshooting 3-51Integrated Management LogThe Compaq Integrated Management Log (IML) records system events and stores them in ane
3-52 Compaq ProLiant ML530 Servers Maintenance and Service GuidePrinting the Event ListNOTE: You can view the event list only from the Recovery/Int
Diagnostics and Troubleshooting 3-53Event MessagesTable 3-21Event MessagesEvent Type Event Message ActionMachine EnvironmentFan Failure System Fan F
3-54 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-21Event Messages continuedEvent Type Event Message ActionPower SubsystemPowe
Diagnostics and Troubleshooting 3-55Rapid Error RecoveryCompaq servers provide rapid recovery services for diagnosing and recovering from errors.The
3-56 Compaq ProLiant ML530 Servers Maintenance and Service GuideThe available recovery features are: Software Error Recovery—Automatically restart
Diagnostics and Troubleshooting 3-57Hardware RequirementsTo use this level of ASR-2 over a modem, you need the following: A third-party PCI or ext
3-58 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-22ASR-2 FeaturesFeatures DefinitionSoftware error recovery If enabled, ASR-2
Diagnostics and Troubleshooting 3-59Compaq Integrated Remote ConsoleThe standard Compaq Integrated Remote Console performs a wide range of configura
Illustrated Parts List 1-3External Components—Spare Parts ListTable 1-1External Components Spare Parts ListItem Description Spare Part NumberChassis
3-60 Compaq ProLiant ML530 Servers Maintenance and Service GuideThe following ASR-2 flow chart shows you the sequence of events after a hardware or
Diagnostics and Troubleshooting 3-61Booting into Compaq UtilitiesWhen you enable ASR-2 to start into Compaq Utilities and a critical error occurs, t
3-62 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-23Compaq System Configuration Utility Pager Settings for Booting into Compaq
Diagnostics and Troubleshooting 3-63Table 3-23Compaq System Configuration Utility Pager Settings for Booting into Compaq Utilities continuedPager Da
3-64 Compaq ProLiant ML530 Servers Maintenance and Service GuideThe System Configuration Utility setting should resemble the following when you enab
Diagnostics and Troubleshooting 3-65ASR-2 Integrated Management Log MessagesThe Integrated Management Log (IML) or Critical Error Log for Server Hea
3-66 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-25ASR-2 IML or Critical Error Log Messages continuedMessage DescriptionNMI –
Diagnostics and Troubleshooting 3-67Revision History TableSome errors can be resolved by reviewing changes to the server configuration. The server h
3-68 Compaq ProLiant ML530 Servers Maintenance and Service GuideStorage Fault Recovery TrackingThis feature tracks over 12 failure-indication parame
Diagnostics and Troubleshooting 3-69Remote Service FeaturesCompaq servers have management features that you can access through a modem or a network,
1-4 Compaq ProLiant ML530 Servers Maintenance and Service GuideSystem Components—Exploded View171920b1815161321a121421bFigure 1-2. System component
3-70 Compaq ProLiant ML530 Servers Maintenance and Service GuideROMPaq Error Recovery OptionsFrom time to time, it may be necessary to upgrade the c
Diagnostics and Troubleshooting 3-71ROMPaq Disaster RecoveryUse the following option with any server that does not have a valid ROM image. 1. Build
3-72 Compaq ProLiant ML530 Servers Maintenance and Service GuideCompaq Insight ManagerCompaq Insight Manager is the Compaq application for easily ma
Diagnostics and Troubleshooting 3-73 SNMP standards—allow integration with other management products. Flexible network conductivity—supports mul
Chapter 4Connectors, Switches, Jumpers, and LEDIndicatorsThis chapter lists connector, switch, jumper, and LED indicator information forCompaq ProLian
4-2 Compaq ProLiant ML530 Servers Maintenance and Service GuideConnectorsThis section contains information about service connectors, ports, and slot
Connectors, Switches, Jumpers, and LED Indicators 4-3System Board ComponentsThe system board connector locations and descriptions for Compaq ProLian
4-4 Compaq ProLiant ML530 Servers Maintenance and Service GuideSwitchesThis section contains information concerning all switches located on Compaq P
Connectors, Switches, Jumpers, and LED Indicators 4-5Jumpers and HeadersCompaq ProLiant ML530 servers system board contains headers with jumpers for
4-6 Compaq ProLiant ML530 Servers Maintenance and Service GuideLED IndicatorsThis section contains information about status and diagnostic LED locat
Illustrated Parts List 1-5System Components—Spare Parts ListTable 1-2System Components Spare Parts ListItem Description Spare Part NumberBoards12 Po
Connectors, Switches, Jumpers, and LED Indicators 4-7PowerThe power status LED on the front panel indicates whether the unit has full power (green)
4-8 Compaq ProLiant ML530 Servers Maintenance and Service GuideMemory ModuleThe memory module (DIMM) diagnostic LED, located adjacent to each memory
Connectors, Switches, Jumpers, and LED Indicators 4-9Hot-Plug FanThe hot-plug fan diagnostic LEDs indicate the condition of each fan in CompaqProLia
4-10 Compaq ProLiant ML530 Servers Maintenance and Service GuideHot-Plug Power SupplyThe hot-plug power supply diagnostic LEDs indicate the conditio
Connectors, Switches, Jumpers, and LED Indicators 4-11Hot-Plug SCSI Hard DriveEach hot-plug SCSI hard drive LED indicates the operational status of
4-12 Compaq ProLiant ML530 Servers Maintenance and Service GuideRJ-45 Network ConnectorThe RJ-45 network connector status LEDs are located on the re
Connectors, Switches, Jumpers, and LED Indicators 4-13CD-ROM DriveThe CD-ROM drive status LED for Compaq ProLiant ML530 servers is located on the
Chapter 5Physical and Operating SpecificationsThis chapter provides operating and performance specifications forCompaq ProLiant ML530 servers and opti
5-2 Compaq ProLiant ML530 Servers Maintenance and Service GuideSystem UnitTable 5-1System Unit SpecificationsDimensionsHeight 51.5 cm (20.3 inch)Dep
Physical and Operating Specifications 5-3Hot-Plug Power SupplyTable 5-2Hot-Plug Power Supply SpecificationsInternational input specificationsNominal
1-6 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 1-2System Components Spare Parts List continuedItem Description Spare Part Numb
5-4 Compaq ProLiant ML530 Servers Maintenance and Service GuideSDRAM Dual Inline Memory ModulesCAUTION: Use only SDRAM DIMMs of the same size, spee
Physical and Operating Specifications 5-5IDE CD-ROM DriveTable 5-532X Max2 IDE CD-ROM Drive SpecificationsDimensionsHeight 4.29 cm (1.9 inch)Width 1
5-6 Compaq ProLiant ML530 Servers Maintenance and Service GuideIntegrated Dual-Channel Wide Ultra2 SCSI ControllerTable 5-6Integrated Dual-Channel W
Physical and Operating Specifications 5-7Hot-Plug Hard DrivesTable 5-7Hot-Plug Hard Drive Specifications9.1 GB 9.1 GB 9.1 GB 18.2 GB 18.2 GB 18.2 GB
IndexSymbols and Numbers10/100 PCI Network InterfaceController See NICAAC circuit overloadwarnings 2-7AC power connector, identified 4-2access p
2 Compaq ProLiant ML530 Servers Maintenance and Service Guidenetwork host name, restartsetting 3-64network IP address, restartsetting 3-64networ
Index 3data transfer rate 5-5depth 5-5height 5-5laser parameters 5-5LEDs, viewing 4-13location 2-19part number 1-3power and signal cab
4 Compaq ProLiant ML530 Servers Maintenance and Service GuideSCSI hard drive 3-36SCSI tape drive 3-37SCSI/IDE CD-ROMdrive 3-36serial port 3-
Index 5Abnormal ProgramTermination 3-65ASR-2 detected by ROM 3-65ASR-2 Test Event 3-65Automatic Server RecoveryBase Memory ParityError 3-65E
6 Compaq ProLiant ML530 Servers Maintenance and Service Guideis failed 3-43is undergoing driverecovery 3-43needs replacing 3-43upload code not
Chapter 2Removal and Replacement ProceduresThis chapter provides subassembly/module-level removal and replacement procedures forCompaq ProLiant ML530
Index 7power supply failure 3-54power supply inserted 3-54power supply notredundant 3-54power supplyremoved 3-54processorCorrectable Error T
8 Compaq ProLiant ML530 Servers Maintenance and Service Guidetechnical support telephonenumbers ixhot surfaceswarnings 2-7, 2-10hot-plug devices
Index 9Mmaintenance and service guide, partnumber 1-6maintenance switchsetting 4-4mass storage deviceslocation 2-19maximum numbersupported 2
10 Compaq ProLiant ML530 Servers Maintenance and Service Guidehard drive blank 1-3hard drive cage blankingpanel 1-3hard drive cage w/backplanebo
Index 11power-on-password, defeating 4-4prefailure alerting 3-73preparationremoval and replacementprocedures 2-4primary CPU fanidentified 2-
12 Compaq ProLiant ML530 Servers Maintenance and Service Guidedrive fan cable and cablebracket 2-18hard drive cage w/backplaneboard 2-22hard dri
Index 13height 5-4read/write heads 5-4rotation 5-4size 5-4transfer rate 5-4hard drives 5-7height 5-7interface 5-7operating temperatu
14 Compaq ProLiant ML530 Servers Maintenance and Service Guidepart number 1-5removing 2-13removing, illustrated 2-13replacing 2-13system fan
Index 15Health Driver 3-59Inspectaccessing 3-2, 3-24description 3-2, 3-4printing Inspect listing 3-4running 3-4Integrated Management Log,d
2-2 Compaq ProLiant ML530 Servers Maintenance and Service GuideElectrostatic Discharge InformationA discharge of static electricity can damage stati
Removal and Replacement Procedures 2-3Symbols on EquipmentAny surface or area of the equipment marked with these symbols indicates thepresence of el
2-4 Compaq ProLiant ML530 Servers Maintenance and Service GuidePreparation ProceduresSystem power in Compaq ProLiant ML530 servers does not complete
Compaq ProLiant ML530 Servers Maintenance and Service GuideNotice© 2000 Compaq Computer CorporationCompaq, Deskpro, Compaq Insight Manager, ProLiant,
Removal and Replacement Procedures 2-5Non-Hot-Pluggable DevicePower must be removed from the server to remove or replace non-hot-pluggable devices.N
2-6 Compaq ProLiant ML530 Servers Maintenance and Service GuideRack WarningsWARNING: To reduce the risk of personal injury or damage to the equipme
Removal and Replacement Procedures 2-7WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment:n The installatio
2-8 Compaq ProLiant ML530 Servers Maintenance and Service GuideTower Model Front Bezel DoorTo remove the tower model front bezel door: 1. Unlock an
Removal and Replacement Procedures 2-9Rack-Mount BezelWARNING: To reduce the risk of personal injury or damage to the equipment, do not use therack
2-10 Compaq ProLiant ML530 Servers Maintenance and Service GuideAccess PanelWARNING: To reduce the risk of personal injury from hot surfaces, allow
Removal and Replacement Procedures 2-11FansCompaq ProLiant ML530 servers ship standard with two hot-pluggable system fans (one CPUand one I/O) and t
2-12 Compaq ProLiant ML530 Servers Maintenance and Service GuideHot-Plug System FansCompaq ProLiant ML530 servers have two system fan baskets, one f
Removal and Replacement Procedures 2-13System Fan Basket AssemblyThe system fan basket assembly is comprised of two components: Plastic system fan
2-14 Compaq ProLiant ML530 Servers Maintenance and Service GuideTo remove the system fan basket-and-cable bracket: 1. Remove the system fan basket.
ContentsAbout This GuideSymbols in Text...viiCom
Removal and Replacement Procedures 2-15CPU Fan Air BaffleTo remove the CPU fan air baffle: 1. Perform the preparation procedures. See “Hot-Pluggabl
2-16 Compaq ProLiant ML530 Servers Maintenance and Service GuideHard Drive Fan Air BaffleTo remove the hard drive fan air baffle: 1. Perform the pr
Removal and Replacement Procedures 2-17Hot-Plug Drive FansThree hot-plug drive fans come standard with Compaq ProLiant ML530 servers.IMPORTANT: It
2-18 Compaq ProLiant ML530 Servers Maintenance and Service GuideDrive Fan Cable and Cable BracketWARNING: To reduce the risk of personal injury or
Removal and Replacement Procedures 2-19Removable Media and Mass Storage DevicesCompaq ProLiant ML530 servers can house up to 16 mass storage devices
2-20 Compaq ProLiant ML530 Servers Maintenance and Service GuideHot-Plug SCSI Hard DrivesCAUTION: Before removing or replacing a hot-plug SCSI hard
Removal and Replacement Procedures 2-21Hard Drive Cage with Backplane BoardCAUTION: If an active hard drive is replaced while the system is powered
2-22 Compaq ProLiant ML530 Servers Maintenance and Service Guide 6. Remove the four T-15 screws securing the hard drive cage to the chassis. 7.
Removal and Replacement Procedures 2-23Removable Media DevicesThe removable media area contains two bays. To remove a device: 1. Perform the prepar
2-24 Compaq ProLiant ML530 Servers Maintenance and Service GuideCD-ROM DriveTo remove the CD-ROM drive: 1. Perform the preparation procedures. See
iv Compaq ProLiant ML530 Servers Maintenance and Service GuideRemoval and Replacement ProcedurescontinuedCable Routing Diagrams ...
Removal and Replacement Procedures 2-25Diskette DriveTo remove the diskette drive: 1. Perform the preparation procedures. See “Powering Down the Se
2-26 Compaq ProLiant ML530 Servers Maintenance and Service GuideCable Routing DiagramsThe location and routing of each cable in Compaq ProLiant ML53
Removal and Replacement Procedures 2-27System Fans-Power Cables12Figure 2-18. Power cables for system fansTable 2-3System Fans—Power CablesItem Des
2-28 Compaq ProLiant ML530 Servers Maintenance and Service GuideSCSI Hard Drives and Removable Media Devices—Signal Cables21Figure 2-19. Signal cab
Removal and Replacement Procedures 2-29CD-ROM and Diskette Drives—Power and Signal Cables231Figure 2-21. Power and signal cables for the CD-ROM and
2-30 Compaq ProLiant ML530 Servers Maintenance and Service GuideSystem Board—Data CableFigure 2-22. System data cableSystem Board—Power Cables21Fig
Removal and Replacement Procedures 2-31SCSI Hard Drives and Removable Media Devices—Power CablesFigure 2-24. Power cables for SCSI hard drives and
2-32 Compaq ProLiant ML530 Servers Maintenance and Service GuideSystem Board TrayWARNING: To reduce the risk of personal injury or damage to the eq
Removal and Replacement Procedures 2-33 4. Press the thumb latch adjacent to the system board tray handle to release the systemboard tray. Using
2-34 Compaq ProLiant ML530 Servers Maintenance and Service GuideSystem Board ComponentsThe system board is mounted to the inside of the tray. When t
Contents vDiagnostics and TroubleshootingcontinuedIntegrated Management Log...
Removal and Replacement Procedures 2-35PCI RetainerTo remove the PCI retainer: 1. Perform the preparation procedures. See “Powering Down the Server
2-36 Compaq ProLiant ML530 Servers Maintenance and Service GuidePCI Expansion BoardsCompaq ProLiant ML530 servers include eight PCI expansion slots,
Removal and Replacement Procedures 2-37PCI BracketTo remove the PCI bracket: 1. Remove all of the PCI expansion boards. See “PCI Expansion Boards”
2-38 Compaq ProLiant ML530 Servers Maintenance and Service GuideMemory ModulesCompaq ProLiant ML530 servers support from 64 MB to a maximum of 4 GB
Removal and Replacement Procedures 2-39To remove an SDRAM DIMM: 1. Perform the preparation procedures. See “Powering Down the Server” earlier in th
2-40 Compaq ProLiant ML530 Servers Maintenance and Service GuideProcessorsCompaq ProLiant ML530 servers support up to two processors. The primary pr
Removal and Replacement Procedures 2-41Hot-Plug Power SuppliesCompaq ProLiant ML530 servers use a hot-plug 450-watt power supply. Only one powersupp
2-42 Compaq ProLiant ML530 Servers Maintenance and Service GuideTo remove a hot-plug power supply:CAUTION: A power supply can only be replaced as a
Removal and Replacement Procedures 2-43Power Supply Blanking PanelCAUTION: When the power supply is not being replaced, cover the opening with apow
2-44 Compaq ProLiant ML530 Servers Maintenance and Service GuidePower Backplane BoardTo remove the power backplane board: 1. Perform the preparatio
Removal and Replacement Procedures 2-45Power On/Standby SwitchTo remove the Power On/Standby switch and cable assembly: 1. Perform the preparation
Chapter 3Diagnostics and TroubleshootingThis chapter describes software and firmware diagnostic tools available for CompaqProLiant ML530 servers. The
3-2 Compaq ProLiant ML530 Servers Maintenance and Service GuideDiagnostic Tools Utility OverviewThe Compaq Diagnostic utilities were developed to as
Diagnostics and Troubleshooting 3-3Table 3-1Diagnostic Tools continuedTool Function ProcedureArray DiagnosticsUtility (ADU)A Windows-based tool desi
3-4 Compaq ProLiant ML530 Servers Maintenance and Service GuideDefault ConfigurationWhen the system is first turned on, the system ROM detects the u
Diagnostics and Troubleshooting 3-5Utilities AccessThe Compaq SmartStart and Support Software CD contains the SmartStart program and manyof the Comp
3-6 Compaq ProLiant ML530 Servers Maintenance and Service GuideRunning the Utilities from Diskette Run the utilities from their individual diskett
Diagnostics and Troubleshooting 3-7Power-On Self-TestPower-On Self-Test (POST) is a series of diagnostic tests that run automatically on Compaqcompu
3-8 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error MessagesError Code Audible Beeps Probable Source of Problem Recom
Diagnostics and Troubleshooting 3-9Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action174-C
About This GuideThis maintenance and service guide is a troubleshooting guide for reference when servicingCompaq ProLiant ML530 servers.IMPORTANT: Th
3-10 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Pr
Diagnostics and Troubleshooting 3-11Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1610
3-12 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Pr
Diagnostics and Troubleshooting 3-13Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1721
3-14 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Pr
Diagnostics and Troubleshooting 3-15Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1764
3-16 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Pr
Diagnostics and Troubleshooting 3-17Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1777
3-18 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Pr
Diagnostics and Troubleshooting 3-19Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Actioncont
viii Compaq ProLiant ML530 Servers Maintenance and Service GuideCompaq Technician NotesWARNING: Only authorized technicians trained by Compaq shoul
3-20 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Pr
Diagnostics and Troubleshooting 3-21Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action* 17
3-22 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Pr
Diagnostics and Troubleshooting 3-23Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1798
3-24 Compaq ProLiant ML530 Servers Maintenance and Service GuideDiagnostics SoftwareThe Test Error Codes tables include all test error codes generat
Diagnostics and Troubleshooting 3-25100–199, Primary Processor Test Error CodesThe 100 series of diagnostic error codes identifies failures with pro
3-26 Compaq ProLiant ML530 Servers Maintenance and Service Guide200–299, Memory Test Error CodesThe 200 series of diagnostic error codes identifies
Diagnostics and Troubleshooting 3-27300–399, Keyboard Test Error CodesThe 300 series of diagnostic error codes identifies failures with keyboard and
3-28 Compaq ProLiant ML530 Servers Maintenance and Service Guide500–599, Video Display Unit Test Error CodesThe 500 series of diagnostic error codes
Diagnostics and Troubleshooting 3-29600–699, Diskette Drive Test Error CodesThe 600 series of diagnostic error codes identifies failures with disket
About This Guide ixWhere to Go for Additional HelpIn addition to this guide, the following information sources are available: User documentation
3-30 Compaq ProLiant ML530 Servers Maintenance and Service Guide800–899, Video Board Test Error CodesThe 800 series of diagnostic error codes identi
Diagnostics and Troubleshooting 3-311200–1299, Modem Communications Test Error CodesThe 1200 series of diagnostic error codes identifies failures wi
3-32 Compaq ProLiant ML530 Servers Maintenance and Service Guide1700–1799, Hard Drive Test Error CodesThe 1700 series of diagnostic error codes iden
Diagnostics and Troubleshooting 3-331900–1999, Tape Drive Test Error CodesThe 1900 series of diagnostic error codes identifies failures with tape ca
3-34 Compaq ProLiant ML530 Servers Maintenance and Service GuideTable 3-14Advanced VGA Board Test Error Codes continuedError Code Description Recomm
Diagnostics and Troubleshooting 3-356000–6099, Compaq NIC Boards Test Error CodesThe 6000 series of diagnostic error codes identifies failures with
3-36 Compaq ProLiant ML530 Servers Maintenance and Service Guide6500–6599, SCSI Hard Drive Test Error CodesThe 6500 series of diagnostic error codes
Diagnostics and Troubleshooting 3-376700–6799, SCSI Tape Drive Test Error CodesThe 6700 series of diagnostic error codes identifies failures with ta
3-38 Compaq ProLiant ML530 Servers Maintenance and Service GuideArray Diagnostic UtilityThe Array Diagnostic Utility (ADU) is a Windows-based softwa
Diagnostics and Troubleshooting 3-39Table 3-20ADU Diagnostic MessagesMessage Description Recommended ActionAcceleratorboard notdetectedArray control
Comments to this Manuals