Hp BL860C User Manual Page 60

  • Download
  • Add to my manuals
  • Print
  • Page
    / 184
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 59
Offline Disk is offline for some other reason.
Inactive Disk has been set inactive.
Not Syncd Data on disk is not synchronized with the rest of
the array.
Primary Disk is the primary disk for a two disk mirror and
is OK.
Secondary Disk is the secondary disk for a two disk mirror
and is OK.
Wrg Type Device is not compatible for use as part of an IM
array.
Too Small Disk is too small to mirror data.
Max Dsks Maximum number of disks allowed for this type
of array has been reached, or maximum number
of total IM disks on a controller has been reached.
No SMART Disk doesn't support SMART and cannot be used
in an RAID array.
Wrg Intfc Device interface (SAS) differs from existing IM
disks.
Pred Fail Indicates whether device SMART is predicting device failure (Yes, No).
Size(MB) Indicates the size of the device in megabytes (megabyte = 1024 x
1024 = 1,048,576 bytes). If the device is part of a two-disk array,
this field reflects the size of the array, not the size of the disk. If the
device is part of a three or more disk array, this field is the size of the
disk within the array.
When creating a striped array, the usable size of the array is
determined by the number of drives multiplied by the size of the smallest
drive in the array. In arrays consisting of different sized drives, excess
space on larger drives is unusable.
Manage Array Screen
The Manage Array screen enables you to manage the current array. To access the Manage Array
screen, select the appropriate field and press Enter on the Manage Array field from the View Array
screen.
The Manage Array screen enables you to perform the following actions:
Manage Hot Spare
To display a Hot Spare Management screen that has the same layout as the Create New Array
screen, press Enter for Manage Hot Spare. This field is grayed out under the following conditions:
The array is inactive.
The array is at its maximum number of devices.
Non-IR firmware is used.
IR is disabled. The array is inactive.
60 Installing the Server Blade Into the Enclosure
Page view 59
1 2 ... 55 56 57 58 59 60 61 62 63 64 65 ... 183 184

Comments to this Manuals

No comments