Possible causesProblem
A corresponding external volume was not found for the external
path with the highest priority.
"?" displays in the LUN ID (Highest Priority) column
of the Discovered External Volumes table (Add
External Volumes window).
Confirm the connection with the external system that failed during
volume discovery, and perform the operation again.
Confirm the connection with the external system; also confirm that
the external volume is correctly configured in the external system,
then perform the operation again.
External volume discovery was not completed
because of failure.
Click Refresh View on the Remote Web Console main window. If
the status remains Checking, perform the reconnect operation again.
After reconnecting an external volume or system,
10 minutes have passed but the status has not
change from Checking.
If the problem persists after a reasonable time, call the HP Technical
Support.
Click Refresh View on the Remote Web Console main window.After disconnecting an external volume or system,
the status does not change from Cache Destage.
Note that the time required for write processing from cache to the
external volume depends on volume capacity. More time is required
for larger volumes. Processing speed is about 20 MB/s. However,
this also depends on the performance and status of the external
system.
If status does not change from Cache Destage after a reasonable
time, call the HP Technical Support.
The device status is currently changing. Wait a few minutes, and
then check the status again. When the transition of the device status
The message, "INTERVENTION REQUIRED", is
issued to the mainframe host as the device status.
has completed normally, the device can be used immediately. If
the device is blocked as a result of the status transition, see the
problem above, "The external volume is blocked".
See the problem above, "The external volume is blocked"The message, “DEVICE ERROR", is issued to the
mainframe host as the device status.
Troubleshooting external path status
The following table shows path statuses in the View External LUN Properties window. Descriptions
and corrective actions you can take are provided.
Also, see Troubleshooting path errors for specific storage systems (page 57).
Corrective actionDescriptionStatus
Call the HP Technical Support.The path status cannot be determined.Unknown
The port is blocked because of microcode
replacement, package replacement, or other
The external port is blocked.Blockade
factor. Check the status of the local storage
system. If you cannot restore the path, call the
HP Technical Support.
The port of the external system is recognized.
See your device manufacturer's documentation
An external system setting has changed. For
example, the path definition was deleted, or the
External device
setting changed
to verify that the settings on the volumes in
question have not changed.
external system itself was replaced by another
device.
Check the external volume capacity. Delete the
external volume, and then remap to it.
The external volume capacity was reduced.LDEV size reduced
The path cannot be used to access the external
system. Check the status of the external system.
The reply of the external system was NOTREADY.
Either the drive is spinning up or the system is
being formatted.
Not ready
If you cannot restore the path, call the HP
Technical Support.
Troubleshooting external path status 55