CAUTION: Indicates that failure to follow directions could result in damage to equipment or data.
IMPORTANT: Provides clarifying information or specific instructions.
NOTE: Provides additional information.
TIP: Provides helpful hints and shortcuts.
General troubleshooting
Check the following table for the problem. After removing an error, retry the operation.
Possible causesProblem
Remote Web Console cannot access the external
volume.
An error occurred in the switch, or the switch is off.
The cables are not properly connected.
The external volume was deleted in the external system.
An error occurred in the external volume.
The path is changed in the external system.
The port attribute in the local storage system is changed.
Topology information is not properly set.
The external volume cannot be mapped.
The number of mapped volumes exceeds the maximum number
(63,232) available for the local storage system.
There are not enough LDKC:CU:LDEV numbers available for
external volume mapping.
The external path is blocked.
See the problem above, “Remote Web Console cannot access
the external volume. If the problem persists after correcting any
errors, continue to the next item.
Confirm that the cable between the local and external system is
connected properly.
If the cable is properly connected, disconnect it and then
reconnect. After 30 seconds, check the path status.
If the path is not restored, call the HP Technical Support.
See Troubleshooting external path status (page 55).Action is required for a path status in the View
External LUN Properties dialog box.
Perform any required action in the message and then retry the
operation. If the problem persists, see Troubleshooting port and
volume discovery problems (page 60).
The volume in the external system cannot be found
even after port discovery or volume discovery was
performed.
The external volume is blocked.
All external paths are blocked (paths are not connected).
The external volume is not set to Read/ Write.
The external volume is blocked by an error.
When errors occur in all external paths, the local storage system
changes the status of the external volume to Blockade.
The status of the external volume is blockade.
Reconnect the volume or storage system.
If the volume’s status still does not change to Normal, restore
the path as described in the problem above, “The external path
is blocked”, and then reconnect the volume again.
54 Support and other resources