Page view 87
72 Chapter 5 Theory of operation
INTR
(initial
rotation)
From the input of a print-
reservation command from the
formatter until the laser/scanner
enters a ready state
z scanner-motor rotation
z fuser/delivery-motor rotation
z drum-motor rotation
z high-voltage control (negative bias to transfer roller)
z receives print command
z fan-motors 1 through 6 full-speed rotation
z pickup operation starts
z high-voltage control bias applied to primary charging roller,
developing roller, and transfer roller)
z fuser control (fuser roller to 190°C [374 °F], pressure roller
180°C [356°F])
z initial rotation final check (high-voltage, scanner motor, pickup
operation complete)
z jam/door open/failure/sleep check
PRINT From the input of a print
command until the primary dc
bias is turned off
z fuser/delivery, drum, scanner, and fan-motor rotations
z fuser control (print temperature—fuser 190°C [374°F])
z engine-to-formatter output signal
z formatter-to-engine input signal
z paper-feed control
z image control
z high-voltage control (toner level-output separation bias and
pressure roller bias)
z next-pickup control (calculates, from media size, the speed to
send media through)
z jam/door open/failure
LSTR
(last
rotation)
From the time the primary
charging roller is turned off until
each of the motors stops
z fuser/delivery, drum, scanner, and fan motor rotations
z high-voltage control completion
z fuser control (print to standby temperature—180°C [356°F])
z fan motor control (fan 1 through 6 full-speed rotation)
z fuser/delivery, drum, and scanner motor stop (writes in
cartridge memory)
z jam/door open/failure check
z ready for next pickup
Table 15. Failure sequence of operation
State Period Operation
JAM From the time the power is
switched on until the end of the
LSTR period
z sensor check
z drive stop (scanner motor, high-voltage, fuser control, and
fuser/delivery motor stop)
z status setting (jam status set)
z door open check
DOOR
OPEN
From the time the power is
switched on until the end of the
LSTR period
z drive stop
z status setting
z door close (wait sequence)
FAILURE From the time the power is
switched on until the end of the
LSTR period
z drive stop
z status setting (set)
Table 14. Normal sequence of operation (continued)
State Period Operation
Page view 87