HP ProCurve 5400zl User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 118
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
1-7
Introducing the ProCurve Series 5400zl Switches
Front of the Switch
Introducing the ProCurve
Series 5400zl Switches
Mgmt
(green/Orange)
On
Off
Blinking
1
A Management module is present and fault free.
The switch is powered off.
There is a fault on the Management module.
PoE
(green/Orange)
On
Off
If any PoE modules are installed.
If no PoE modules are installed.
Blinking
1
Blinking
2
Internal PoE fault.
External load fault or denied PoE power.
Temp
(green/Orange)
Off Switch temperature is normal.
Blinking
1
An over temperature condition has been detected.
Fan
(green/Orange)
On The cooling fans are operating normally.
Blinking
1
One or more of the cooling fans have failed. The switch Fault LED will be blinking
simultaneously.
Internal Power
(green/Orange -
numbers
corresponding to
the power supply
positions)
On A power supply is installed in the position in the back of the switch corresponding to the
number, and the supply is plugged in to an active AC power source. As shipped, the switch
has a single power supply in position 1.
Off A power supply is not installed in the position corresponding to the number.
Blinking
1
The power supply installed in the position corresponding to the number is not plugged in
to an active AC power source, or has experienced a fault. The switch Fault LED will be
blinking simultaneously.
EPS
(green/Orange)
On
Off
An External Power Supply is connected.
No External Power Supply is connected.
Blinking
1
The External Power Supply has a fault, or is connected but not plugged into AC power.
Modules (green -
letters
corresponding to
the switch
module slots)
In PoE Mode:
On A module is installed in the switch module slot corresponding to the letter and the module
is undergoing or has passed self test. This also occurs when you install a module when
the switch is already powered on (“hot swap”).
Off A module is not installed in the switch module slot corresponding to the letter.
Blinking
1
On
Blinking
1
Blinking
2
Off
The module status LED flashes very briefly when a module is being hot swapped. If the LED
flashes for a prolonged time, the module in the slot corresponding to the letter has failed
self test or encountered some other fault condition. See chapter 4, “Troubleshooting” for
a more information.
PoE is ok for this slot.
PoE internal fault for this slot.
PoE load fault or insufficient power for this slot.
The module in this slot is not a PoE module.
LEDs State Meaning
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 117 118

Comments to this Manuals