Page view 95
318 HSG80 Users Guide
require any more disk drives than mirrorsets, this storageset is an
excellent choice for data that warrants mirroring.
Considerations for Planning a Striped Mirrorset
Plan the mirrorset members, then plan the stripeset that will contain
them. Review the recommendations in Considerations for Planning a
Stripeset, page 310, and Considerations for Planning a Mirrorset,
page 312.
There are the following limitations for a striped mirrorset:
A maximum of 24 mirrorsets in a stripeset.
A maximum of 6 disks in each mirrorset.
A maximum of 48 disks in the entire striped mirrorset.