Hp Array Controller HSG V8.7 Software User Manual Page 442

  • Download
  • Add to my manuals
  • Print
  • Page
    / 576
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 441
D–8 HSG80 User’s Guide
Nonvolatile Parameter Memory Component Event Sense Data Response
The HSG80 controller Executive software component reports errors
detected while accessing a Nonvolatile Parameter Memory Component
via the Nonvolatile Parameter Memory Component Event Sense Data
Response (see Figure D–5).
Instance Codes (byte offset 32-35) are described in Table D–1,
ā€œInstance Codesā€ on page D–18.
ASC and ASCQ codes (byte offsets 12 and 13) are described in
Table D–7, ā€œASC and ASCQ Codesā€ on page D–85.
Figure D–5 Template 11 - Nonvolatile Parameter Memory
Component Event Sense Data Response Format
off bit 7 6 5 4 3 2 1
Unusd
Unused
Unused
Unused
Unused
Unused
Unused
Error Code
0
1
2
3-6
7
8-11
12
13
14
15–17
18–31
32-35
36
37
38–53
54–69
70–73
74–75
76
77-103
104–107
108–111
112–114
115
116–159
0
Sense Key
Additional Sense Length
Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Reserved
Reserved
Reserved
Reserved
Instance Code
Template
Template Flags
Controller Board Serial Number
Controller Software Revision Level
Memory Address
Byte Count
Number of Times Written
Undefined
Reserved
LUN Status
CXO6178A
Page view 441
1 2 ... 437 438 439 440 441 442 443 444 445 446 447 ... 575 576