Hp Array Controller HSG V8.7 Software User Manual Page 433

  • Download
  • Add to my manuals
  • Print
  • Page
    / 576
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 432
LED Codes C–9
■●●❍❍❍❍
30 The JSRAM battery is bad Replace controller
■●●❍❍●❍
32 First-half diagnostics of the Time of
Year Clock failed
Replace controller
■●●❍❍●●
33 Second-half diagnostics of the Time of
Year Clock failed
Replace controller
■●●❍●❍●
35 The processor bus-to-device bus bridge
chip is bad
Replace controller
■●●●❍●●
3B There is an unnecessary interrupt
pending
Replace controller
■●●●●❍❍
3C There was an unexpected fault during
initialization
Replace controller
■●●●●❍●
3D There was an unexpected maskable
interrupt during initialization
Replace controller
■●●●●●❍
3E There was an unexpected NMI during
initialization
Replace controller
■●●●●●●
3F An invalid process ran during
initialization
Replace controller
Table C–2 Flashing OCP Patterns (Continued)
Pattern
OCP
Code
Error Repair Action
Page view 432
1 2 ... 428 429 430 431 432 433 434 435 436 437 438 ... 575 576

Comments to this Manuals

No comments