LED Codes C9
■●●❍❍
30 The JSRAM battery is bad Replace controller
■●●❍❍●❍
32 First-half diagnostics of the Time of
Year Clock failed
Replace controller
■●●❍❍●●
33 Second-half diagnostics of the Time of
Year Clock failed
Replace controller
■●●❍●❍●
35 The processor bus-to-device bus bridge
chip is bad
Replace controller
■●●●❍●●
3B There is an unnecessary interrupt
pending
Replace controller
■●●●●❍
3C There was an unexpected fault during
initialization
Replace controller
■●●●●❍
3D There was an unexpected maskable
interrupt during initialization
Replace controller
■●●●●●
3E There was an unexpected NMI during
initialization
Replace controller
■●●●●●
3F An invalid process ran during
initialization
Replace controller
Table C2 Flashing OCP Patterns (Continued)
Pattern
OCP
Code
Error Repair Action