Service Hours—Displays the number of hours in service.
Total Moves—Displays the total number of moves.
Door Status—Displays the tape library door status. The following values are valid:
Open—Indicates that the tape library door is open.
Closed—Indicates that the tape library is closed.
Not supported—Indicates that the tape library does not detect or report door status.
Unknown—The door status of the tape library cannot be determined. Ensure the latest
drivers and Storage Agents are installed.
Temperature—Displays the tape library temperature status. The following values are valid:
OK—Indicates that the temperature of the library is within normal operating limits.
Safe Temperature Exceeded—Indicates that the temperature of the library has exceeded
the safe operational temperature. The library continues to operate under this warning.
Maximum Temperature Exceeded—Indicates that the temperature of the library has
exceeded the normal operating limits to the extent that the library might no longer function.
Not supported—Indicates that the library cannot detect or report the temperature status.
Unknown—The temperature status of the tape library cannot be determined. Ensure the
latest drivers and Storage Agents are installed.
Redundancy—Displays the tape library redundancy status, which denotes the presence of
internal redundant components, such as fans, power supplies, etc. The following values are
valid:
Active—Indicates that the library is capable of detecting and reporting redundant
components, there are enough redundant units already installed, and the redundancy is
active.
Capable—Indicates that the library is capable of detecting and reporting redundant
components but there are not enough redundant units installed to make redundancy active.
Not capable—Indicates that the library is capable of detecting and reporting redundant
components but there are no components that support redundancy.
Not supported—Indicates that the library cannot detect or report redundancy status.
Unknown—The redundancy status of the tape library cannot be determined. Ensure the
latest drivers and Storage Agents are installed.
Hot Swap—Displays the tape library hot swap status which denotes the presence of hot
swappable internal components, such as drives, fans, power supplies, etc. The following
values are valid:
Capable—Indicates that the library is capable of detecting and reporting hot-swappable
internal components and has at least one hot-swappable component.
Not capable—Indicates that the library is capable of detecting and reporting hot
swappable internal components but there are no hot-swappable components installed.
Not supported—Indicates that the library cannot detect or report hot-swap status.
Unknown—The hot-swap status of the tape library cannot be determined. Ensure the latest
drivers and Storage Agents are installed.
Last Known Error—Displays the hexadecimal error status code including text information, if
available. For details, see the hardware documentation for more information.
Associated Tape Drives—Displays a list of tape drives associated with the tape storage system.