Connection Type displays the type of connection between the server and the box. The following
values are possible:
Fibre Attached - This chassis is attached to the server through Fibre Channel.
SCSI Attached - This chassis is attached to the server with a SCSI cable.
SAS Attached - This chassis is attached to the server with a SAS cable.
Unknown - The Storage Agents are unable to determine the type of connection.
Serial Number displays the storage system chassis serial number, which is normally displayed
on the front panel. Use this information for identification purposes.
IO Slots displays whether an array controller is installed. If an array controller is installed then
the type of array controller is displayed. The following values are possible:
Not Installed - An array controller is not installed in the IO slot.
Fibre Array - A Fibre Channel array controller is installed in the IO slot.
SCSI Array - A SCSI array controller is installed in the IO slot.
Unknown Array - The Storage Agents cannot identify the type of array controller installed
in the IO slot. The Storage Agents may need to be upgraded to a later version.
Unknown - The Storage Agents are unable to determine what is installed in the IO slot.
IO Module Type displays the storage system chassis SCSI I/O module type that is installed.
The following values are possible:
2 Port Ultra3 SCSI Module - A 2 Port Ultra3 SCSI I/O Module is installed.
4 Port Shared Storage Module - A 4 Port Shared Storage Module for the Smart Array
Cluster Storage is installed.
4 Port - Upgrade Firmware - A 4-Port Shared Storage Module for the Smart Array Cluster
Storage is installed, but the current controller firmware does not support it. The controller
firmware must be upgraded.
2 Port Ultra320 SCSI Module - A 2 Port Ultra320 SCSI I/O Module is installed.
4 Port Ultra320 SCSI Module - A 4 Port Ultra320 SCSI I/O Module is installed.
1 Port Ultra320 SCSI Module - A 1 Port Ultra320 SCSI I/O Module is installed.
Unknown - The Storage Agents cannot determine the IO module type for this storage
system.
RSO Status displays the status of the Recovery Server Option. Two servers are connected to
the storage system so that when one fails the other server takes control of the storage system.
The following values are possible:
OK - The recovery server option is installed and the other server is working correctly.
Secondary Running - Auto - The recovery server option is installed, but the secondary
(standby) server is running in place of the primary server. The secondary server assumed
control automatically.
Secondary Running - User - The recovery server option is installed, but the secondary
(standby) server is running in place of the primary server. The secondary server assumed
control via manual intervention.
Link Down - The recovery server option is installed, but the communications link to the
secondary (standby) server is down.
No Secondary - The recovery server option is installed, but the communications link to
the secondary (standby) server has never been established.