Hp Insight Management Agents User Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 177
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
Not Authenticated—The physical drive could not be authenticated as a genuine HP hard
drive. The array controller will no longer control the drive LEDs. Please replace the hard
drive with a genuine HP hard drive.
Unknown—The physical drive cannot be monitored at this time. This may be due to:
The device driver for this drive may have been unloaded.
The logical drive may have failed and been deactivated by the operating system. In
this case, the last known status was OK.
The Storage Agents do not recognize the drive. You may need to upgrade your
software.
Action—Displays the action that is required for this device. The following values are valid:
Replace Drive—Replace this drive. If the drive condition is Failed, check the Predictive
Indicators, Problem Indicators, and Failure Indicators for a possible cause of the failure.
Replace S.M.A.R.T. Drive—The S.M.A.R.T. hard drive predicts imminent failure. Schedule
replacement of the drive before an actual failure occurs.
No Action Required—The drive is operating normally and no action is required.
Authentication Status—Displays the authentication status for this device. The following values
are valid:
Authentication Passed—The physical drive has passed all authentication tests and has
been validated to be a genuine HP hard drive.
Authentication Failed—The physical drive could not be authenticated as a genuine HP
hard drive. The array controller will no longer control the drive LEDs. Replace the hard
drive with a genuine HP hard drive.
Unknown—The Storage Agents cannot determine the physical drive's authentication
status.
Capacity—Displays the size of the physical drive.
Model—Displays a description of the physical drive. The text depends on the manufacturer
of the drive and the drive type.
If a drive fails, note the model to identify the type of drive necessary for replacement.
Firmware Version—Displays the physical drive firmware version number. Make sure you have
the most recent version of the firmware because older versions may not support all of the
newest features.
Smart Carrier Application Firmware Version—Displays the physical drive smart carrier
application firmware version number of the Smart Carrier that passed authentication.
Smart Carrier Bootloader Firmware Version—Displays the physical drive smart carrier
bootloader firmware version number of the Smart Carrier that passed authentication.
Serial Number—Displays the serial number assigned to the physical drive. This value is based
on the serial number as returned by the SCSI inquiry command but may be modified due to
space limitations. This item can be used for identification purposes.
Service Hours—Displays the current number of hours of service (the number of hours that a
physical drive has been spinning) since the drive was stamped. The drive was stamped when
it left the factory.
For example, if the Current Service Hours value is 604, the drive has been operating for 604
hours. If an error occurred at 499 Service Hours, it occurred after 499 hours of service.