HP xw6400 User's Guide Page 142

  • Download
  • Add to my manuals
  • Print
  • Page
    / 208
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 141
Screen message Probable cause Recommended action
917—Front Audio Not
Connected
The front audio cable is not connected. Connect front audio cable.
918—Front USB Not
Connected
Front USB is not connected. Connect front USB cable.
919—MultiBay Riser Not
Connected
MultiBay riser is not connected. Connect MultiBay riser.
920—Fan Command 2 Pin
Connector from Power Supply
Not Connected
The 2-pin fan connector from the
power supply is not connected.
Connect 2-pin fan connector.
940—Extended ROM
signature not found
The signature at the start of the ROM
flash is missing. Your firmware (BIOS)
is incomplete.
Run ROMPaq again.
960—CPU Overtemp
occurred
The ambient temperature could
exceed operating limits
(maximum=95˚F), or there are
obstructions to airflow, including dust
build up.
1. Be sure you are not operating the system in an
environment that exceeds 95˚F.
2. Disconnect power and open the access panel.
3. Verify that cables are not blocking CPU heatsink
fans or front fan, if installed.
4. Verify that there is not excessive dust on major
components.
5. If airflow is acceptable and there is not excessive
dust, the thermal sensing circuitry has failed on the
processors or on the system board. You must
replace the processors and/or the system board.
1151—Serial Port 1 Address
Conflict Detected
Both external and internal serial ports
are assigned to COM1.
1. Remove any Comm port expansion cards.
2. Clear CMOS.
3. Reconfigure card resources and run Computer
Setup (F10 Setup).
4. Run Computer Setup or Windows utilities.
1152—Serial Port 2 Address
Conflict Detected
Both external and internal serial ports
are assigned to COM2.
1. Remove any Comm port expansion cards.
2. Clear CMOS.
3. Reconfigure card resources and run Computer
Setup (F10 Setup).
4. Run Computer Setup or Windows utilities.
1155—Serial Port Address
Conflict Detected
Both external and internal serial ports
are assigned to same IRQ.
1. Remove any Comm port expansion cards.
2. Clear CMOS.
3. Reconfigure card resources and run Computer
Setup (F10 Setup).
4. Run Computer Setup or Windows utilities.
1201—System Audio Address
Conflict Detected
Device IRQ address conflicts with
another device.
Reset the IRQ.
1202—MIDI Port Address
Conflict Detected
Device IRQ address conflicts with
another device.
Reset the IRQ.
Table 5-18 POST error messages (continued)
132 Chapter 5 System diagnostics and troubleshooting ENWW
Page view 141
1 2 ... 137 138 139 140 141 142 143 144 145 146 147 ... 207 208

Comments to this Manuals

No comments