Software Fixes Release Notes for 07.8.04
36
36440 The routing switch does not forward the MAC group
address 01-80-C2-00-00-03 that was filtered by an
IEEE 802.1D MAC bridge.
MAC
Addressing
07.8.02
38066 When you add a single, multicast static MAC
address to a port that is a member of a VLAN may
result in packet loss.
MAC
Addressing
07.8.02
38276 When you install a n EP 8 Port Mini-GBIC
Redundant Management module in a routing
switch, an error message indicating an unsupported
DMA version is displayed.
System 07.8.02
38383 When you remove a 1-Port 10 Gigabit Ethernet
module, the following error message is displayed:
Error - IP routing was configured on
ports 14/48
System 07.8.02
39902 A routing switch configured with rate limiting caused
a system reload when an invalid port data entry was
accessed.
Rate Limiting 07.8.02
40150 Adding a VLAN to a VLAN group creates an invalid
VLAN number. For example, if you add VLAN 181
to VLAN Group 200, VLAN 181200 is added to the
VLAN group.
VLAN 07.8.02
41967 Changes to the running configuration and startup
configuration during an SSH session may report the
IP address 0.0.0.0 in the trap and Syslog messages
for the Telnet client.
SSH 07.8.02
43422 A next-hop movement message is displayed on the
console when a station is moved and an ARP entry
is deleted.
IP Stack 07.8.02
44042 On an EP 8 Port Mini-GBIC Redundant
Management module, a system reload occurs when
an SSH session is closed with inconsistent data.
SSH 07.8.02
44046 When you connect an Ethernet loopback cable to a
port on an EP 48-Port 10/1000-TX RJ45 module,
the port goes into forwarding state and interrupts
the flow of traffic.
System 07.8.02
45575 A routing switch sends the configured nas-port-
type value to the RADIUS server instead of to the
NAS port for MAC authentication.
MAC
Authentication
07.8.02
47163 On an EP 8 Port Mini-GBIC Redundant
Management module, a start-of-packet counter is
incorrectly displayed in the RX_NO_SOP_CNT
counters.
System 07.8.02
Bug ID Bug Description Protocol/
Feature
Version
Found
Version
Fixed
Page view 38