Software Fixes Release Notes for 07.8.04
26
07.8.01
14668 Although rare in occurrence, in some configurations
with EBGP, IBGP, and OSPF routes, a routing
switch may not always select the best route. For
example, the device might install an IBGP route in
the routing table, even though the IBGP route has a
higher administrative distance than OSPF. This
could happen if the switch previously selected an
EBGP route as the best route.
If this problem occurs, you must clear the routing
table for a routing switch to select the best route.
BGP 07.8.01
25042 On the EP 8 Port Mini-GBIC Redundant
Management module, if you configure a port name
on the primary port of a trunk group, the switch
generates an error message when it boots up. For
example, the following configuration generates an
error at boot-up:
ProCurve(config)#interface ethernet
1/3
ProCurve(config-if-e1000-1/3)# port-
name “testtrunk”
However, if you configure a port name on all of the
members of the trunk group, this error does not
occur. For example:
ProCurve(config)#trunk switch ethernet
1/3 to 1/4
ProCurve(config-trunk-1/3-1/4)#port-
name “testtrunk”
CLI 07.8.01
25049,
25455
A port operating at 10-half (10 Mbps at half duplex)
drops 80% of broadcast traffic to other ports in the
VLAN. This does not occur if the port is configured
to operate at 100-full.
IP Stack 07.8.01
29177 On an 8 Port Mini-GBIC Redundant Management
module, a deny clause in an outbound ACL does
not filter traffic correctly if the destination IP address
has been aggregated using the IP net aggregate
command.
ACL 07.8.01
29465 On an EP 24 Port 100Base-FX module (J8178A),
MRP disables 10/100 copper MRP ring interfaces
that are set to 100-full speed and duplex mode. In
addition, the show interface brief command output
displays the interfaces as “blocked”.
24-port 10/100
Module
07.8.01
29469 The peer MAC address or IP field for the VSRP
standby displays “unknown” even if the VSRP
standby knows the IP address of the master routing
switch.
VSRP 07.8.01
Bug ID Bug Description Protocol/
Feature
Version
Found
Version
Fixed