8 HP TippingPoint S1000 Series
WARNING! Do not attempt to install a DC power supply into an NGFW Appliance. The NGFW
Appliance does not contain the grounding capability for safe installation of a DC power supply. Bodily
harm and damage to the system could result.
Cabling Requirements
The S1050F appliance ships with the following cables:
• One AC power cable
• Null modem cable for the serial console management port (DB-9 to RJ-45) shown in Figure 2-3 on
page 7.
Technical Specifications
The S1050F appliance has the following specifications:
Installing the Appliance
To install and complete installation setup of the appliance, see ”Installing the NGFW Appliance” on
page 21.
Table 2-2 S1050F Appliance Hardware Specifications
Specification Description
Dimensions
(unpackaged)
1.73 in (H) x 16.78 in (W) x 17.72 in (D)
(4.40 cm x 42.62 cm x 45.00 cm)
Weight 15.28 lbs (6.93 kg)
Power
Requirements
AC: Voltage 100 – 240; Current 4 – 2 A; Frequency 50 – 60 Hz
The appliance’s maximum power consumption is 142 W.
Service Provider
operating
requirements
Temperature: 32 – 104° F (0 – 40° C) — Operating
Temperature: -4 – 158° F (-20 – 80° C) — Storage
Altitude: No degradation up to 10,000 feet (3048 m)
Humidity: 5% to 95% (non-condensing)
External interfaces • 1 – 1GbE copper management port
•1 – RJ-45 console port
• 8 – 1GbE copper ports
• 1 external storage card drive
Comments to this Manuals