http://www.hp.com/support/ma nuals
Click Disk Storage Systems under Storage, and then select the appropriate product under
EVA Disk Arra ys.
If the disk is running an unsupported version of rmware, download the correct rmware from
the following website and install it using the instructions included with the rmware le. Do not
add the disk to a disk group if it is running an unsupported rm w are version.
h
ttp://www.hp.com/support/evadiskrmware
NOTE:
When downloading the rm ware, use the disk model number to locate the corr ect rmware
le. If you have difculty locating the correct rmware, contact your HP-authorized service
r epresentative for assistance.
If you are running XCS 6.000, verify that leveling is not in progress before upgrading the disk drive
rmw are. In HP Command View EVA, go to the General tab of the Disk Group Pr operties window
and verify that the Leveling eld displays Inactive. If it displays Active, wait for leveling to complete
before performing the upgrade. This does not apply if you are running XCS 6.100 or later.
Figure 40 Chec king model number and rmware version
Adding the disk to a disk group
After replacing the disk, add it to a disk group. The disk is t ypically added back into its original disk
group.
1. In the N avigation pane, select Storage system > Hardware > Rack > Disk enclosure > Bay.
2. In the Content pane, select the Disk Drive tab.
3. Click Group to initiate the process for adding the disk to a disk group.
Operation Successful is displayed indicating the disk is now grouped and leveling has
been initiated. The storage system begins immediately using the disk.
NOTE:
If the Device Addition Policy is set to automatic, the disk is automatically added to a disk group. In
this case the Group option will not be available.
Returning the failed component
Follow the return instructions provided with the new component.
Replacing the disk enclosure power supply/blower
This section describes the procedure for replacing the power supply/blower assembly.