Changing the De
vice Addition Policy
To prevent the s
torage system from automatically grouping a new disk drive that may have the incorrect
rmware on it, t
he Device Addition Policy must be checked and set to manual if necessary:
1. Open Command View VA and in the Navigation pane select the storage system.
The Initialized Storage System Properties window opens.
2. Click System O
ptions.
3. Select Set system operational policies.
4. IftheDeviceAdditionPolicyissettoAutomatic, change it to Manual.
5. Click Save ch
anges.
NOTE:
If you want to return the Device Addition Policy to automatic, use the above procedure to do so after
verifying the disk drive has the correct rmware version.
Installing the disk drive
1. Push in the ejector button on the disk drive and pu ll the release lever down to the full open position.
2. Insertthedriveintotheenclosureasfarasitwillgo(1,Figure 8).
3. Close the release lever until it engages the ejector button, and the disk drive seats in the backplane
(2 , Figure 8).
4. Press in rmly on the disk drive to ensure it is seated properly.
1
1
2
0116a
Figure 8 Ins talling the disk drive
Checking status indicators
After replacing the disk drive, check the following to verify that the disk drive is operating normally:
NOTE:
It may take up to 10 minutes for the c omponent to display good status.
Check the disk drive status indicators. See Figure 9.
•Activityindicator(1)shouldbeonorashing
O nline indicator (2) should be on or ashing
Fault indicator (3) should be off
Check the following using HP Command View EVA.